Number of found documents: 208
Published from to

Determination of Inorganic Arsenic in Samples of Marine Origin
Marschner, Karel; Matoušek, Tomáš; Dědina, Jiří; Musil, Stanislav
2017 - English
A fast screening method for determination of inorganic arsenic in marine samples was developed. This method is based on selective\nhydride generationanddetectionby inductively coupled plasmamass spectrometry. Using a high concentration of hydrochloric acid\ntogether with hydrogen peroxide for hydride generation leads to selective conversion of inorganic arsenic species into arsane. The\naccuracy of this method was verified by comparative analyse by high performance liquid chromatography coupled with hydride generationandatomic\nfluorescence detection. Keywords: arsenic speciation; inorganic arsenic; hydride generation Available on request at various institutes of the ASCR
Determination of Inorganic Arsenic in Samples of Marine Origin

A fast screening method for determination of inorganic arsenic in marine samples was developed. This method is based on selective\nhydride generationanddetectionby inductively coupled plasmamass ...

Marschner, Karel; Matoušek, Tomáš; Dědina, Jiří; Musil, Stanislav
Ústav analytické chemie, 2017

Fate of smelter dusts in temperate and semi-arid soils
Ettler, V.; Jarošíková, A.; Mihaljevič, M.; Kříbek, B.; Veselovský, F.; Penížek, V.; Vaněk, A.; Šráček, O.; Matoušek, Tomáš; Mapani, B.; Kamona, F.; Nyambe, I.
2017 - English
Our results indicate that, compared to semi-arid areas (where inorganic contaminants are rather immobile in soils despite their high concentrations), a higher potential risk exists in smelter-affected humid areas, where metal(loid) contaminants can be easily released by extensive weathering of particulates in the soil systems. Keywords: soils; smelter dusts Available in digital repository of the ASCR
Fate of smelter dusts in temperate and semi-arid soils

Our results indicate that, compared to semi-arid areas (where inorganic contaminants are rather immobile in soils despite their high concentrations), a higher potential risk exists in smelter-affected ...

Ettler, V.; Jarošíková, A.; Mihaljevič, M.; Kříbek, B.; Veselovský, F.; Penížek, V.; Vaněk, A.; Šráček, O.; Matoušek, Tomáš; Mapani, B.; Kamona, F.; Nyambe, I.
Ústav analytické chemie, 2017

CECE 2016. 13th International Interdisciplinary Meeting on Bioanalysis
Foret, František; Křenková, Jana; Drobníková, Iveta; Klepárník, Karel
2016 - English
This year the meeting included full texts of 32 oral and 78 poster presentations delivered by participants from 17 countries. The attached conference proceedings, edited by highly cited scientists, documents the quality of the meeting. Similarly to the previous years the lectures were given by outstanding, highly cited, scientists. The list of speakers as well as more detailed information about the conference can be found on its permanent web at www.ce-ce.org. Keywords: bioanalysis; separation; biotechnology Fulltext is available at external website.
CECE 2016. 13th International Interdisciplinary Meeting on Bioanalysis

This year the meeting included full texts of 32 oral and 78 poster presentations delivered by participants from 17 countries. The attached conference proceedings, edited by highly cited scientists, ...

Foret, František; Křenková, Jana; Drobníková, Iveta; Klepárník, Karel
Ústav analytické chemie, 2016

Development of microfluidic device for droplet generation and microparticle encapsulation
Křivánková, Jana; Foret, František
2016 - English
Microfluidic devices combined with various bioanalytical and optical sensors proved\ntheir potential in chemical, biological, and biomedicine applications. At a droplet\nmicrofluidic device a fluid is divided into numerous droplets surrounded by a\ncontinuous immiscible fluid phase. Generated droplets serve then as\nvessels/microcapsules for delivering drugs, nutrients as well as for encapsulating of\nbiologically active particles and cells.\nDescribed experimental study deals with the development of a practical dropletbased\nmicrofluidic chip useful for production of monodisperse water/oil emulsion and\nfor encapsulation of thin-metal magnetic microsheets. Keywords: microfluidic device; microparticle encapsulation Available in digital repository of the ASCR
Development of microfluidic device for droplet generation and microparticle encapsulation

Microfluidic devices combined with various bioanalytical and optical sensors proved\ntheir potential in chemical, biological, and biomedicine applications. At a droplet\nmicrofluidic device a fluid is ...

Křivánková, Jana; Foret, František
Ústav analytické chemie, 2016

Subsidiary reagens for improvement of enzymatic digestion protocol
Laštovičková, Markéta; Bobáľ, P.; Flodrová, Dana; Bobálová, Janette
2016 - English
In this report, we demonstrate the influence of hydrogen peroxide, phenol and\nacetonitrile on enzymatic digestion of proteins accomplished during common bottomup\nproteomic identifications. Keywords: proteomic identifications; MALDI-TOF MS; enzymatic digestion; peptides Available in digital repository of the ASCR
Subsidiary reagens for improvement of enzymatic digestion protocol

In this report, we demonstrate the influence of hydrogen peroxide, phenol and\nacetonitrile on enzymatic digestion of proteins accomplished during common bottomup\nproteomic identifications.

Laštovičková, Markéta; Bobáľ, P.; Flodrová, Dana; Bobálová, Janette
Ústav analytické chemie, 2016

Determination of dicarboxylic acids in atmospheric aerosols using ion chromatography with on-line connected preconcentration unit
Čapka, Lukáš; Mikuška, Pavel; Večeřa, Zbyněk
2016 - English
A method for the fast and sensitive detection of dicarboxylic acids in atmospheric\naerosols was optimized. The method is based on the online sampling and subsequent\nanalysis with ion chromatography. The system was applied to the determination of\nDCAs in urban aerosols in Brno. The method was verified using a laboratory generated\nstandard aerosol of DCAs. A sampling of aerosol particles on parallel filter was used\nas a reference method. Keywords: atmospheric aerosols; dicarboxylic acids; aerosol collector; ion chromatography Available in digital repository of the ASCR
Determination of dicarboxylic acids in atmospheric aerosols using ion chromatography with on-line connected preconcentration unit

A method for the fast and sensitive detection of dicarboxylic acids in atmospheric\naerosols was optimized. The method is based on the online sampling and subsequent\nanalysis with ion chromatography. ...

Čapka, Lukáš; Mikuška, Pavel; Večeřa, Zbyněk
Ústav analytické chemie, 2016

Investigation of bioactive proteins in pressurized water extract of Sambucus nigra L. branches
Hohnová, Barbora; Šalplachta, Jiří; Roth, Michal
2016 - English
Investigation of high-value substances in plant materials has been of increasing interest\nin last years. In this study, PHWE, SDS-PAGE and MALDI-TOF techniques were\nemployed for investigation of bioactive proteins in Sambucus nigra L. branches. Keywords: extraction of bioactive proteins; MALDI-TOF/TOF mass spectrometry; Sambucus nigra L. branches; SDS-PAGE; PHWE Available in digital repository of the ASCR
Investigation of bioactive proteins in pressurized water extract of Sambucus nigra L. branches

Investigation of high-value substances in plant materials has been of increasing interest\nin last years. In this study, PHWE, SDS-PAGE and MALDI-TOF techniques were\nemployed for investigation of ...

Hohnová, Barbora; Šalplachta, Jiří; Roth, Michal
Ústav analytické chemie, 2016

Combined effect of temperature and CdO nanoparticles treatment on Picea abies
Večeřová, Kristýna; Mikuška, Pavel; Oravec, Michal; Kozáčiková, Michaela; Pompeiano, Antonio; Coufalík, Pavel; Urban, Otmar
2016 - English
Three-years old seedlings of Picea abies were pre-treated under two different\ntemperatures (20x35 °C) and subsequently exposed to elevated concentration of CdO\nnanoparticles (CdONPs). Two-week exposure to airborne CdONPs of ecologically\nrelevant size and concentration significantly reduced photosynthetic light use efficiency\nin plants as well as contents of photosynthetic pigments and saccharides. In contrary,\namino acid content was increased under CdONPs. These changes were further\nmodulated by previous growth temperature. Keywords: Picea abies; terrestrial ecosystems; CdO nanoparticles Available in digital repository of the ASCR
Combined effect of temperature and CdO nanoparticles treatment on Picea abies

Three-years old seedlings of Picea abies were pre-treated under two different\ntemperatures (20x35 °C) and subsequently exposed to elevated concentration of CdO\nnanoparticles (CdONPs). Two-week ...

Večeřová, Kristýna; Mikuška, Pavel; Oravec, Michal; Kozáčiková, Michaela; Pompeiano, Antonio; Coufalík, Pavel; Urban, Otmar
Ústav analytické chemie, 2016

Highly sensitive analysis of chlorophenols and sulfonamides in waters by electrophoretic focusion on inverse electromigration dispersion gradient with ESI-MS detection
Malá, Zdeňka; Gebauer, Petr; Boček, Petr
2016 - English
This work presents a new methodology for high-sensitivity analyses by capillary\nelectrophoresis (CE) with electrospray-ionization mass spectrometric (ESI-MS)\ndetection, based on electrophoretic focusing on an inverse electromigration dispersion\n(EMD) gradient. The technique is based on a robust electrolyte system providing a\ngradient of required properties, suitable for routine analyses of trace amounts of weak\nacids with pKa values between approx. 6.5 and 9. Examples analyses of several\nchlorophenols and sulfonamides are presented, with LODs around 3x10-9 M for spiked\ndrinking water without any sample pretreatment. Keywords: capillary electrophoresis; electrospray-ionization mass spectrometric detection; chlorophenols; sulfonamides Available in digital repository of the ASCR
Highly sensitive analysis of chlorophenols and sulfonamides in waters by electrophoretic focusion on inverse electromigration dispersion gradient with ESI-MS detection

This work presents a new methodology for high-sensitivity analyses by capillary\nelectrophoresis (CE) with electrospray-ionization mass spectrometric (ESI-MS)\ndetection, based on electrophoretic ...

Malá, Zdeňka; Gebauer, Petr; Boček, Petr
Ústav analytické chemie, 2016

Screening of acyclovir permeation through skin using alaptide
Bobálová, Janette; Černíková, A.; Bobáľ, P.; Jampílek, J.
2016 - English
This investigation deals with the affection of the permeation of acyclovir through fullthickness\npig ear skin using a Franz diffusion cell from the donor vehicle of propylene\nglycol/water (1:1) using synthesised (S)-8-methyl-6,9-diazaspiro[4.5]decane-7,10-\ndione, alaptide as a potential transdermal permeation enhancer. Keywords: acyclovir permeation; chemical permeation enhancers; skin permeation experiments Available on request at various institutes of the ASCR
Screening of acyclovir permeation through skin using alaptide

This investigation deals with the affection of the permeation of acyclovir through fullthickness\npig ear skin using a Franz diffusion cell from the donor vehicle of propylene\nglycol/water (1:1) ...

Bobálová, Janette; Černíková, A.; Bobáľ, P.; Jampílek, J.
Ústav analytické chemie, 2016

About project

NRGL provides central access to information on grey literature produced in the Czech Republic in the fields of science, research and education. You can find more information about grey literature and NRGL at service web

Send your suggestions and comments to nusl@techlib.cz

Provider

http://www.techlib.cz

Facebook