Number of found documents: 216
Published from to

Study of mechanical properites of nanostructured polymer coatings prepared using plasma enhanced chemical vapor deposition
Buršíková, V.; Homola, V.; Peřina, Vratislav
2015 - English
The aim of the present work was to deposit transparent polymer SiOxCyHz protective coatings from hexamethyldisiloxane/ oxygen mixtures in capacitively coupled glow discharge. The coatings prepared under dusty plasma conditions showed nanocomposite character. Complex characterization of the local mechanical properties was carried out on the prepared samples from nano to microscale using indentation techniques. The coatings were very elastic, they exhibited high elastic recovery and low plastic deformation even at indentation depths approaching the coating thickness. Keywords: PECVD; hexamethyldisiloxane; mechanical properties Available at various institutes of the ASCR
Study of mechanical properites of nanostructured polymer coatings prepared using plasma enhanced chemical vapor deposition

The aim of the present work was to deposit transparent polymer SiOxCyHz protective coatings from hexamethyldisiloxane/ oxygen mixtures in capacitively coupled glow discharge. The coatings prepared ...

Buršíková, V.; Homola, V.; Peřina, Vratislav
Ústav jaderné fyziky, 2015

RESPONSE OF SURFACE MORPHOLOGY IN COBALT-FULLERENE MIXTURE FILMS UPON VARIATION OF THE METAL CONTENT
Lavrentiev, Vasyl; Lavrentieva, Inna; Vacík, Jiří
2015 - English
The morphology and roughness of the films show great change around some critical composition x(c) of the mixture film (x(c) approximate to 3). The films with lower Co content (x < 3) is rather smooth and the roughness is rather low. However, if x >= 3, the roughness of the CoxC60 films dramatically increases and sharp protrusions appear on the surface that reflects an important phase transformation in the film structure. The obtained AFM results define the concentration interval of the Co solubility in solid C-60 (x < 3), which was found to be narrower than that evaluated from spectroscopic experiments (see the text). This interval suggests a formation of the Co1C60 and Co2C60 fullerides in the CoxC60 mixtures where the Co atoms occupy the tetrahedral holes in the fullerene lattice. The dramatic change of the surface morphology at x >= 3 reflects the pronounced Co clustering which likely occurs due to numerical filling the octahedral pores. Formation of the protrusions on the surface of the supersaturated CoxC60 mixture films (x > 3) is a consequence of the compressive stress arising in the film due to the Co clustering. Keywords: Fullerene; Cobalt; mixture; roughness; surface; phase transformation Available at various institutes of the ASCR
RESPONSE OF SURFACE MORPHOLOGY IN COBALT-FULLERENE MIXTURE FILMS UPON VARIATION OF THE METAL CONTENT

The morphology and roughness of the films show great change around some critical composition x(c) of the mixture film (x(c) approximate to 3). The films with lower Co content (x ...

Lavrentiev, Vasyl; Lavrentieva, Inna; Vacík, Jiří
Ústav jaderné fyziky, 2015

Residual Stress Distribution Measurement by Neutron Diffraction of the Single Pass Fillet Steel Welds
Mráz, Ľ.; Karlsson, L.; Vrána, Miroslav; Mikula, Pavol
2014 - English
In this contribution the results of residual strain/stress measurements performed on several single pass fillet steel welds which were carried out at different welding conditions, namely, with different filler materials are presented. Keywords: residual stress; neutron diffraction; steel welds Available at various institutes of the ASCR
Residual Stress Distribution Measurement by Neutron Diffraction of the Single Pass Fillet Steel Welds

In this contribution the results of residual strain/stress measurements performed on several single pass fillet steel welds which were carried out at different welding conditions, namely, with ...

Mráz, Ľ.; Karlsson, L.; Vrána, Miroslav; Mikula, Pavol
Ústav jaderné fyziky, 2014

Determination of reference values of element contents in certified reference material SWCNT-1 by INAA a PGAA
Kučera, Jan; Sturgeon, R. E.; Grinberg, P.; Oflaz, R.; Paul, R. L.; Bennett, J. W.; De Nadai Fernandes, E. A.; Kubešová, Marie; Bacchi, M. A.; Stopic, A. J.
2014 - Czech
Instrumental neutron activation analysis with both relative and k-0 standardization was used in four experienced laboratories to determine element mass fractions in single-wall carbon nanotube certified reference material (CRM) SWCNT-1. Results obtained were evaluated using the NIST “Type B On Bias” approach and yielded consensus values in agreement with NRCC certified values for Fe, Co, Ni and Mo and provided mass fraction values for thirteen additional elements, namely Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Br, La, W and Au. In addition, prompt gamma neutron activation analysis was employed to determine mass fractions of H, B, Co, Ni, and Mo. Results of this work provide a basis for the establishment of reference values of element mass fractions in CRM SWCNT-1, thus expanding its usability for more accurate characterization and benchmarking of similar nanotechnology materials. Keywords: carbon nanotubes; neutron activation analysis Available at various institutes of the ASCR
Determination of reference values of element contents in certified reference material SWCNT-1 by INAA a PGAA

Instrumental neutron activation analysis with both relative and k-0 standardization was used in four experienced laboratories to determine element mass fractions in single-wall carbon nanotube ...

Kučera, Jan; Sturgeon, R. E.; Grinberg, P.; Oflaz, R.; Paul, R. L.; Bennett, J. W.; De Nadai Fernandes, E. A.; Kubešová, Marie; Bacchi, M. A.; Stopic, A. J.
Ústav jaderné fyziky, 2014

A comparative study of the total mercury determination in highly contaminated soils by AAS and RNAA methods
Sysalová, J.; Kučera, Jan; Zvěřina, O.
2014 - English
Výsledky srovnávací studie stanovení celkové rtuti ve vysoce kontaminovaných půdách do obsahu 25 mg/kg byly získány dvěma nezávislými metodami: metodou AAS s použitím jednoúčelového spektrometru AMA-254 s přímým dávkováním 10-25 mg pevných vzorků a metodou neutronové aktivační analýzy s radiochemickou separací (RNAA) s navážkami 150 mg vzorků. Vzorky půd byly upravovány sítováním a kryogenním mletím. Kontrola kvality výsledků byla provedena analýzami certifikovaných referenčních materiálů NIST SRM 2711 Montana Soil a NIST SRM 2711a Montana Soil II. Pro vyšší obsahy rtuti nad 25 mg/kg, byly vzorky ředěny mořským pískem v poměru 1:10 a homogenizovány před dávkováním do AMA-254. Proces ředění vzorků v pevném stavu byl ověřen analýzou říčního sedimentu ERM-CC580. Výsledky analýz celkových obsahů rtuti v kontaminovaných půdách získané nezávislými metodami AAS a RNAA vykazují velmi dobrou shodu pro oba uvedené postupy. High total mercury (T-Hg) contents in soils, up to 25 mg kg−1, were determined by two independent methods: a one-purpose atomic absorption spectrometer AMA-254 (Advanced Mercury Analyser) with direct solid sampling, and radiochemical neutron activation analysis (RNAA), using sample masses of 10 mg to 25 mg and about 150 mg, respectively. An excellent agreement between results of both methods was obtained. For quality control (QC) purposes, NIST SRM 2711 Montana Soil and NIST SRM 2711a were analysed by both methods using the above sample masses. The results obtained were compared with the NIST certified values within the uncertainty margins, thus proving the accuracy of the procedures employed. It has been found that the cryogenic grinding used provided sufficiently representative and homogeneous samples. A test in which HgS was analysed by RNAA showed that even mercury present in sulfide form would be fully recovered using the procedures employed. For contents of T-Hg above the upper limit of the AMA-254 working range (500 ng), samples were firstly diluted with sea sand in the ratio 1:10 and homogenised well to get RSD below 5%. The dilution procedure was verified using the certified reference material ERM-CC580 Estuarine Sediment. Keywords: mercury; RNAA; Advanced Mercury Analyser Available at various institutes of the ASCR
A comparative study of the total mercury determination in highly contaminated soils by AAS and RNAA methods

Výsledky srovnávací studie stanovení celkové rtuti ve vysoce kontaminovaných půdách do obsahu 25 mg/kg byly získány dvěma nezávislými metodami: metodou AAS s použitím jednoúčelového spektrometru ...

Sysalová, J.; Kučera, Jan; Zvěřina, O.
Ústav jaderné fyziky, 2014

Nedestruktivní stanovení dusíku v biologických a jiných materiálech fotonovou aktivační analýzou
Krausová, Ivana; Mizera, Jiří; Chvátil, David; Krist, Pavel; Řanda, Zdeněk; Kučera, Jan; Štursa, Jan
2013 - Czech
Byl vyvinut postup instrumentální gama aktivační analýzy (IGAA) pro stanovení dusíku v biologických materiálech. Stanovení je založeno na měření nespecifického anihilačního záření gama o energii 511 keV emitovaného 13N, který je produktem fotojaderné reakce 14N(γ, n)13N a je čistým pozitronovým zářičem. Metoda IGAA umožnila stanovení dusíku pod úrovní 1 hmotnostního procenta ve vybraných biolgických referenčních materiálech - NIST RM 8433 Corn Bran, 1547 Peach Leaves, 8414 Bovine Muscle, and 1577b Bovine Liver. Optimalizovaný postup byl také použit pro stanovení dusíku v práškových nanodiamantech pro lékařské účely. A procedure has been developed for assaying nitrogen in biological materials by means of instrumental photon activation analysis (IPAA). The determination has been based on counting of the non-specific 511 keV annihilation gamma rays of 13N, product of the photonuclear reaction 14N(γ, n)13N and a pure positron emitter. IPAA allowed determination of nitrogen down to 1 wt.%. in selected biological reference standards - NIST RM 8433 Corn Bran, 1547 Peach Leaves, 8414 Bovine Muscle, and 1577b Bovine Liver. The optimized procedure was applied also to assaying nitrogen in pulverized nanodiamond intended for medical purposes. Keywords: instumental photon activation analysis; nitrogen; biological materials; nanodiamond Available at various institutes of the ASCR
Nedestruktivní stanovení dusíku v biologických a jiných materiálech fotonovou aktivační analýzou

Byl vyvinut postup instrumentální gama aktivační analýzy (IGAA) pro stanovení dusíku v biologických materiálech. Stanovení je založeno na měření nespecifického anihilačního záření gama o energii 511 ...

Krausová, Ivana; Mizera, Jiří; Chvátil, David; Krist, Pavel; Řanda, Zdeněk; Kučera, Jan; Štursa, Jan
Ústav jaderné fyziky, 2013

K otázce lokalizace mateřského kráteru australoasijských tektitů: Geochemické, izotopové, geografické a balistické faktory
Mizera, Jiří; Řanda, Zdeněk
2013 - Czech
Soubor australoasijských tektitů (AAT) byl geochemicky charakterizován metodami aktivační analýzy. Na základě získaných výsledků a dříve publikovaných geochemických, mineralogických, petrografických a izotopových dat pro AAT a jejich potencionální zdrojové materiály, spolu s uvážením geografických a balistických omezení známých pro jiné tektity a jejich pádová pole, jsou diskutovány pravděpodobné zdrojové materiály a lokalizace mateřského impaktového kráteru pro AAT. A set of Australasian tektites (AAT) has been geochemically characterized by methods of activation analysis. Based on the acquired data as well as previously published geochemical, mineralogical, petrographical and isotopic data on both AAT and their potential source materials, and considering geographic and ballistic constraints known from other tektites and their strewn fields, probable source materials and location of the parent impact crater for AAT have been discussed. Keywords: Australasian tektites; impact; parent crater; activation analysis Available at various institutes of the ASCR
K otázce lokalizace mateřského kráteru australoasijských tektitů: Geochemické, izotopové, geografické a balistické faktory

Soubor australoasijských tektitů (AAT) byl geochemicky charakterizován metodami aktivační analýzy. Na základě získaných výsledků a dříve publikovaných geochemických, mineralogických, petrografických a ...

Mizera, Jiří; Řanda, Zdeněk
Ústav jaderné fyziky, 2013

Jak počítat nejistoty parametrů neutronového toku a výsledků analýzy při použití k0-NAA
Kubešová, Marie; Kučera, Jan
2013 - Czech
Byla vypracována nová metoda výpočtu nejistot parametrů neutronového toku, hmotnostních frakcí prvků a jejich nejistot v k0-neutronové aktivační analýze (k0-NAA) použitím Kragtenova univerzálního tabulkového procesoru. Získané výsledky jsou porovnány s jinými přístupy hodnocení nejistot parametrů neutronového toku a hmotnostních frakcí prvků obsaženými v programech Kayzero for Windows, k0-IAEA a ERON. A novel method has been developed for the calculation of uncertainties of neutron flux parameters and element mass fractions and their uncertainties in k0-neutron activation analysis (k0-NAA) using the Kragten universally applicable spreadsheet technique. The results obtained are compared with other approaches for evaluation of uncertainties of the neutron flux parameters and element mass fractions, namely with the Kayzero for Windows, k0-IAEA and ERON programs. Keywords: k0-neutron activation analysis; uncertainties of neturon flux parameters; Kragten spreadsheet technique Available at various institutes of the ASCR
Jak počítat nejistoty parametrů neutronového toku a výsledků analýzy při použití k0-NAA

Byla vypracována nová metoda výpočtu nejistot parametrů neutronového toku, hmotnostních frakcí prvků a jejich nejistot v k0-neutronové aktivační analýze (k0-NAA) použitím Kragtenova univerzálního ...

Kubešová, Marie; Kučera, Jan
Ústav jaderné fyziky, 2013

Stanovení prvkových nečistot v polymerních materiálech elektrických kabelů bezpečnostních systémů jaderných elektráren neutronovou aktivační analýzou
Kučera, Jan; Kubešová, Marie; Bartoníček, B.
2013 - Czech
Instrumentální neutronová aktivační analýza (INAA) byla použita k prvkové charakterizaci jednotlivých součástí elektrických kabelů v současnoti používaných v bezpečnostních systémech jaderných elektráren (JE). Analýzou byla získána informace o obsazích 35 prvků. Bylo zjištěno, že kabely nesplňují požadavky na kvalifikaci pro novou generaci JE podle „The European Utility Requirements for LWR Nuclear Power Plants”, protože obsahy několika prvků přesáhly maximální přípustné hodnoty pro nečistoty. Bylo prokázáno, že INAA je vhodnou metodou pro prvkovou charakterizaci polymerních materiálů elektrických kabelů při jejich kvalifikaci pro použití v JE. Instrumental neutron activation analysis (INAA) was employed for elemental characterization of individual components of electrical cables currently used in safety systems of nuclear power plants (NPP). The analysis yielded information about the content of 35 elements. It has been found that the cables do not satisfy requirements of qualification set for the new generation of NPP by „The European Utility Requirements for LWR Nuclear Power Plants”, because content of several elements exceeded the maximal impurity levels. INAA proved to be a method of choice for elemental characterization of polymer materials of electrical cables as part of their qualification for use in NPP. Keywords: instumental neutron activation analysis; polymer materials of electrical cables; impurity levels; qualification for use in nuclear power plants Available at various institutes of the ASCR
Stanovení prvkových nečistot v polymerních materiálech elektrických kabelů bezpečnostních systémů jaderných elektráren neutronovou aktivační analýzou

Instrumentální neutronová aktivační analýza (INAA) byla použita k prvkové charakterizaci jednotlivých součástí elektrických kabelů v současnoti používaných v bezpečnostních systémech jaderných ...

Kučera, Jan; Kubešová, Marie; Bartoníček, B.
Ústav jaderné fyziky, 2013

Stanovení jódu v biologických materiálech neutronovou aktivační analýzou
Kučera, Jan
2012 - Czech
Jsou vyhodnoceny výhody a nevýhody různých postupů neutronové aktivační analýzy (NAA), zejména instrumentální NAA (INAA), epithermální NAA (ENAA) a radiochemické NAA (RNAA) pro stanovení jódu v biologických materiálech, zejména ve vzorcích potravin a stravy. Jsou uvedeny příklady stanovení jódu ve vzorcích stravy z Asie metodami ENAA a RNAA. Správnost výsledků byla potvrzena analýzou četných biologických referenčních materiálů amerického NIST. The advantages and disadvantages of various modes of neutron activation analysis (NAA), such as instrumental NAA (INAA), epithermal NAA (ENAA), and radiochemical NAA (RNAA) for iodine determination in biological materials, namely in food and diet samples are briefly reviewed. Examples are given of iodine determination in Asian diet samples by ENAA and RNAA. The accuracy of the results obtained was proved by analyses of numerous US NIST reference materials (RMs) of biological origin. Keywords: Iodine; neutron activation analysis; food; diet Available at various institutes of the ASCR
Stanovení jódu v biologických materiálech neutronovou aktivační analýzou

Jsou vyhodnoceny výhody a nevýhody různých postupů neutronové aktivační analýzy (NAA), zejména instrumentální NAA (INAA), epithermální NAA (ENAA) a radiochemické NAA (RNAA) pro stanovení jódu v ...

Kučera, Jan
Ústav jaderné fyziky, 2012

About project

NRGL provides central access to information on grey literature produced in the Czech Republic in the fields of science, research and education. You can find more information about grey literature and NRGL at service web

Send your suggestions and comments to nusl@techlib.cz

Provider

http://www.techlib.cz

Facebook

Other bases