Neostel collimator realization detailed optical design
Lédl, Vít; Pleštil, Jan; Psota, Pavel; Steiger, Lukáš; Václavík, Jan; Tomáš, V.
2017 - anglický
The aim of this document is to describe the optical design of the Alignment Collimator for the NEOSTEL telescope. The document describes proposed optical and mechanical design. It consists of several parts: Optical design and its tolerance analysis, Ghost image analysis, Stray light analysis, Mechanical design and FEM analysis. Klíčová slova: collimator; FEM; alignment; telescope; optical design Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Neostel collimator realization detailed optical design

The aim of this document is to describe the optical design of the Alignment Collimator for the NEOSTEL telescope. The document describes proposed optical and mechanical design. It consists of several ...

Lédl, Vít; Pleštil, Jan; Psota, Pavel; Steiger, Lukáš; Václavík, Jan; Tomáš, V.
Ústav fyziky plazmatu, 2017

CNT composite - polishing methods and metalic coating
Thoř, Tomáš; Václavík, Jan; Vápenka, David
2017 - anglický
This study summarizes R&D tasks done in order to develop technology for polishing and metallic coating of CNT composite for optical and radiofrequency applications. Development was done on two types of material samples:\n- Material for the MIRROR demonstrator\n- Material for the FEEDHORN demonstrator Klíčová slova: polishing; cnt composite; metallic coating Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
CNT composite - polishing methods and metalic coating

This study summarizes R&D tasks done in order to develop technology for polishing and metallic coating of CNT composite for optical and radiofrequency applications. Development was done on two types ...

Thoř, Tomáš; Václavík, Jan; Vápenka, David
Ústav fyziky plazmatu, 2017

Methodology of camera spectral response measurement
Melich, Radek; Václavík, Jan; Žídek, Karel
2016 - anglický
Spectral response of the camera will be measured using monochromator in conjunction with an integration sphere. Camera without objective will be placed in one port of the integrating sphere and light beam from monochromator will be fed into perpendicular port. Sensor of the camera sensor will be therefore uniformly illuminated by diffused light from monochromator. Proposed FWHM of the monochromator is 15 nm as a trade-off between light intensity provided by monochromator and deformation of spectral characteristic (Picture XY). Diameter of the integrating sphere has to be larger than 100 mm to ensure uniform illumination over sensor area. Klíčová slova: Camera spectral response Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Methodology of camera spectral response measurement

Spectral response of the camera will be measured using monochromator in conjunction with an integration sphere. Camera without objective will be placed in one port of the integrating sphere and light ...

Melich, Radek; Václavík, Jan; Žídek, Karel
Ústav fyziky plazmatu, 2016

Evaluation of selected parameters of a LIBA2000 glass melt according to ISO 12123.
Václavík, Jan
2016 - anglický
Measurement of refractive indices of samples, specifically refractive indicies nd, ne and Abbe numbers for spectral lines d and e. Assesment of refractive index variation, internal spectal transmitance and amount of striae in samples.\n Klíčová slova: glass melt; ISO 12123; striae; refractive index; inhomogeneity Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Evaluation of selected parameters of a LIBA2000 glass melt according to ISO 12123.

Measurement of refractive indices of samples, specifically refractive indicies nd, ne and Abbe numbers for spectral lines d and e. Assesment of refractive index variation, internal spectal ...

Václavík, Jan
Ústav fyziky plazmatu, 2016

Device calibration.
Melich, Radek; Václavík, Jan; Žídek, Karel
2016 - anglický
The device has to be calibrated in absolute terms for its brightness response. This will be facilitated by a combination of an integrating sphere and collimating objective. The emitted total light intensity will be controlled by a reference photodiode inside the integrating sphere. Klíčová slova: absolute brightness calibration Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Device calibration.

The device has to be calibrated in absolute terms for its brightness response. This will be facilitated by a combination of an integrating sphere and collimating objective. The emitted total light ...

Melich, Radek; Václavík, Jan; Žídek, Karel
Ústav fyziky plazmatu, 2016

METIS mirror M0 FS
Lédl, Vít; Melich, Radek; Vít, Tomáš
2016 - anglický
Scope of the document is to provide required test results with respect to the structure of M0 mirror, FS version. The mirror has a unique numbering M0-C17-20. Klíčová slova: METIS M0 mirror Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
METIS mirror M0 FS

Scope of the document is to provide required test results with respect to the structure of M0 mirror, FS version. The mirror has a unique numbering M0-C17-20.

Lédl, Vít; Melich, Radek; Vít, Tomáš
Ústav fyziky plazmatu, 2016

PROBA3 Coronograph System Progress Report
Horodyská, Petra; Melich, Radek
2016 - anglický
The scope of this document is to provide to CSL and ESTEC a progress report of ongoing activities as described in Project Management Plan v1_1. TOPTEC main activities cover realization of coronagraph optical elements, housing for this elements, HDD and the Lyot stop realization. In year 2016, the DM model was finished and delivered and the STM model was competely realized and delivered. Toptec started to prepare the documents for Critical Design Review (CDR). Klíčová slova: coronagraph optical elements; housing; HDD; Lyot stop; DM; STM Plné texty jsou dostupné na vyžádání prostřednictvím repozitáře Akademie věd.
PROBA3 Coronograph System Progress Report

The scope of this document is to provide to CSL and ESTEC a progress report of ongoing activities as described in Project Management Plan v1_1. TOPTEC main activities cover realization of coronagraph ...

Horodyská, Petra; Melich, Radek
Ústav fyziky plazmatu, 2016

METIST mirror M1 FS
Lédl, Vít; Melich, Radek; Vít, Tomáš
2016 - anglický
Scope of the document is to provide required test results with respect to the structure and optical performance of individual optical surfaces of M1 mirror, FS version. The mirror has a unique numbering M1-C20-23. Klíčová slova: METIS mirror M1 FS Plné texty jsou dostupné na vyžádání prostřednictvím repozitáře Akademie věd.
METIST mirror M1 FS

Scope of the document is to provide required test results with respect to the structure and optical performance of individual optical surfaces of M1 mirror, FS version. The mirror has a unique ...

Lédl, Vít; Melich, Radek; Vít, Tomáš
Ústav fyziky plazmatu, 2016

METIS mirror M2 FS
Lédl, Vít; Melich, Radek; Vít, Tomáš
2016 - anglický
Scope of the document is to provide required test results with respect to the structure and optical performance of individual optical surfaces of M2 mirror FS version. The mirror has a unique numbering M2-C21-24. Klíčová slova: METIS mirror M2 FS Plné texty jsou dostupné na vyžádání prostřednictvím repozitáře Akademie věd.
METIS mirror M2 FS

Scope of the document is to provide required test results with respect to the structure and optical performance of individual optical surfaces of M2 mirror FS version. The mirror has a unique ...

Lédl, Vít; Melich, Radek; Vít, Tomáš
Ústav fyziky plazmatu, 2016

Selection process of an observation objective with respect to minimal glare level
Melich, Radek; Václavík, Jan; Žídek, Karel
2016 - anglický
An observation objective (OO) that will image the projection screen on the camera detector is necessary to choose in a such a way that its glare performance is traced. This objective feature is not documented by an objective supplier, therefore we design a procedure that enable us to relatively compare the objective between each other. Klíčová slova: objective glare Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Selection process of an observation objective with respect to minimal glare level

An observation objective (OO) that will image the projection screen on the camera detector is necessary to choose in a such a way that its glare performance is traced. This objective feature is not ...

Melich, Radek; Václavík, Jan; Žídek, Karel
Ústav fyziky plazmatu, 2016