Number of found documents: 457
Published from to

Polycyklické aromatické uhlovodíky v PM1 aerosolu na 6 lokalitách v České republice
Křůmal, Kamil; Mikuška, Pavel
2019 - Czech
PAHs byly měřeny v zimní sezóně ve městech Ostrava-Radvanice (průmyslová lokalita), Brno, Mladá Boleslav, Kladno-Švermov, Čelákovice, Košetice (pozaďová lokalita). Z koncentrací PAHs v PM1 aerosolu byly počítány rizika vzniku rakoviny plic. PAHs were measured in winter seasons in cities/towns Ostrava-Radvanice (industrial city), Brno, Mladá Boleslav, Kladno-Švermov, Čelákovice, Košetice (background town). Lifetime lung cancer risks of PAHs were calculated from concentrations of PAHs in PM1 aerosol. Keywords: PAHs; PM1; lung cancer risk Available in digital repository of the ASCR
Polycyklické aromatické uhlovodíky v PM1 aerosolu na 6 lokalitách v České republice

PAHs byly měřeny v zimní sezóně ve městech Ostrava-Radvanice (průmyslová lokalita), Brno, Mladá Boleslav, Kladno-Švermov, Čelákovice, Košetice (pozaďová lokalita). Z koncentrací PAHs v PM1 aerosolu ...

Křůmal, Kamil; Mikuška, Pavel
Ústav analytické chemie, 2019

Microfluidic device for cell counting and electrical lysis
Václavek, Tomáš; Křenková, Jana; Foret, František
2018 - English
This lecture presents two microfluidic devices as essential units for single cell proteomic analysis, firstly a device for cell counting based on resistive pulse sensing as an alternative to optical platforms based on visual control over the sample input, secondly a unit for electrical lysis of cells using direct current voltage pulses to lyse cells one by one with a possibility to analyze the distinct lysate zones by electrospray ionization mass spectrometry. Keywords: microfluidic devices; microextraction of basic drugs; single cell proteomic analysis; electrospray ionization mass spectrometry; cell lysis Fulltext is available at external website.
Microfluidic device for cell counting and electrical lysis

This lecture presents two microfluidic devices as essential units for single cell proteomic analysis, firstly a device for cell counting based on resistive pulse sensing as an alternative to optical ...

Václavek, Tomáš; Křenková, Jana; Foret, František
Ústav analytické chemie, 2018

Impact of post-harvest processing, geographical locality and production year on quality of selected medicinal plants
Burdějová, Lenka; Polovka, M.; Pořízka, J.
2018 - English
This study deals with the assessment of the impact of post-harvest treatment, geographical location and production years on 32 selected characteristics of medicinal plants grown in the Czech Republic. Dimethyl sulfoxide herbal extracts characteristics were evaluated by spectroscopic and chromatographic techniques. The results were processed by analysis of variance and multivariate statistical tools. Obtained results clearly proved the successful differentiation of herbal samples by means of canonical discrimination analysis according to post-harvest treatment (100%), geographical origin (82.9%) and production year (96.1%) confirming that studied factors may have significant effect on quality of medicinal plants. Keywords: HPLC-DAD; ICP-OES; plants extracts; herbal extracts Fulltext is available at external website.
Impact of post-harvest processing, geographical locality and production year on quality of selected medicinal plants

This study deals with the assessment of the impact of post-harvest treatment, geographical location and production years on 32 selected characteristics of medicinal plants grown in the Czech Republic. ...

Burdějová, Lenka; Polovka, M.; Pořízka, J.
Ústav analytické chemie, 2018

A Validatation of non-invasive method for diagnostic of cystic fibrosis based on ion ratios determined by CE-C4D
Ďurč, P.; Lačná, J.; Dosedělová, V.; Foret, František; Homoľa, L.; Pokojová, E.; Malá, M.; Skřičková, J.; Dastych, M.; Vinohradská, H.; Dřevínek, P.; Skalická, V.; Kubáň, Petr
2018 - English
A validation of novel approach for diagnosis of cystic fibrosis (CF) is presented. The method is very simple and fast, since for collection of samples, only wiping of the skin of forearm is needed. The collected sample is analyzed by capillary electrophoresis with contactless conductometric detection (CE-C4D). Ion ratios are determined as ratios of peak area of chloride anion and peak areas of selected cations. It is possible to distinguish between cystic fibrosis patients and healthy individuals when ion ratio is applied as diagnostic factor. In here, we present analytical parameters of developed method (limits of detection, limits of quantification, repeatability of migration times, repeatability of peak areas) and ROC curve, which reveals high sensitivity and specificity of the developed method. Keywords: method for diagnostic of cystic fibrosis; cystic fibrosis; capillary electrophoresis with contactless conductometric detection Fulltext is available at external website.
A Validatation of non-invasive method for diagnostic of cystic fibrosis based on ion ratios determined by CE-C4D

A validation of novel approach for diagnosis of cystic fibrosis (CF) is presented. The method is very simple and fast, since for collection of samples, only wiping of the skin of forearm is needed. ...

Ďurč, P.; Lačná, J.; Dosedělová, V.; Foret, František; Homoľa, L.; Pokojová, E.; Malá, M.; Skřičková, J.; Dastych, M.; Vinohradská, H.; Dřevínek, P.; Skalická, V.; Kubáň, Petr
Ústav analytické chemie, 2018

Acetonitrile-assisted enzymatic digestion used for analysis of proteins of cancer origin
Laštovičková, Markéta; Bobál, P.; Strouhalová, Dana; Bobálová, Janette
2018 - English
In this study, in-gel trypsin digestion protocol using aqueous-acetonitrile solvent system was developed to facilitate bottom-up proteomic identification of proteins isolated from human breast cancer cells. Keywords: breast cancer cells; enzymatic digestion; MS analysis Fulltext is available at external website.
Acetonitrile-assisted enzymatic digestion used for analysis of proteins of cancer origin

In this study, in-gel trypsin digestion protocol using aqueous-acetonitrile solvent system was developed to facilitate bottom-up proteomic identification of proteins isolated from human breast cancer ...

Laštovičková, Markéta; Bobál, P.; Strouhalová, Dana; Bobálová, Janette
Ústav analytické chemie, 2018

Optimization of photochemical vapor generation of molybdenum as a sample introduction for ICP-MS
Šoukal, Jakub; Musil, Stanislav
2018 - English
Conditions of photochemical vapor generation of molybdenum with ICP-MS detection have been in detail investigated. Keywords: ICP-MS; molybdenum; photochemical vapor generation Available at various institutes of the ASCR
Optimization of photochemical vapor generation of molybdenum as a sample introduction for ICP-MS

Conditions of photochemical vapor generation of molybdenum with ICP-MS detection have been in detail investigated.

Šoukal, Jakub; Musil, Stanislav
Ústav analytické chemie, 2018

Droplet-based microfluidic chip with passive mixer for analysis with photon-upconversion nanoparticles
Křivánková, Jana; Přikryl, Jan; Hlaváček, Antonín
2018 - English
Mixing of the fluids in microfluidic chips is important especially in applications, where droplet contents need to be rapidly homogenized. Here, a passive method for mixing in polydimethylsiloxane (PDMS) microchannels is presented. Droplet homogenization was firstly tested with organic stains and subsequently applied for mixing water dispersions of photon-upconversion nanoparticles (UCNPs).\n Keywords: microfluidic chips; microfluidic systems; photon-upconversion nanoparticles Fulltext is available at external website.
Droplet-based microfluidic chip with passive mixer for analysis with photon-upconversion nanoparticles

Mixing of the fluids in microfluidic chips is important especially in applications, where droplet contents need to be rapidly homogenized. Here, a passive method for mixing in polydimethylsiloxane ...

Křivánková, Jana; Přikryl, Jan; Hlaváček, Antonín
Ústav analytické chemie, 2018

Supercritical water in etching and morphing of siliceous surfaces for analytical separations
Karásek, Pavel; Horká, Marie; Planeta, Josef; Roth, Michal
2018 - English
Applications of supercritical water in etching and morphing of siliceous surfaces for analytical separations are briefly reviewed. Keywords: supercritical water; fused silica capillary; electromigration methods Available in digital repository of the ASCR
Supercritical water in etching and morphing of siliceous surfaces for analytical separations

Applications of supercritical water in etching and morphing of siliceous surfaces for analytical separations are briefly reviewed.

Karásek, Pavel; Horká, Marie; Planeta, Josef; Roth, Michal
Ústav analytické chemie, 2018

Capillary electrophoresis in clinical diagnosis and monitoring
Kubáň, Petr
2018 - English
There is a significant potential of CE to provide a useful analytical tool to analyze noninvasive samples of body fluids and stimulate the cooperation between analytical chemists and clinicians in this interdisciplinary field. Keywords: CE; CE-LIF; clinical diagnosis Available in digital repository of the ASCR
Capillary electrophoresis in clinical diagnosis and monitoring

There is a significant potential of CE to provide a useful analytical tool to analyze noninvasive samples of body fluids and stimulate the cooperation between analytical chemists and clinicians in ...

Kubáň, Petr
Ústav analytické chemie, 2018

Measuring photon-upconversion luminiscence from droplets in microfluidic chips
Hlaváček, Antonín; Křivánková, Jana; Přikryl, Jan
2018 - English
UCNPs are lanthanide-doped nanocrystals that can be excited by near-infrared light and emit light of shorter wavelengths. Advantages of UCNPs include multiple and narrow emission bands, negligible autofluorescence and high photostability, which make UCNPs ideal luminescence label for use in droplet microfluidic. Here, we introduce the instrumentation for reading photon-upconversion luminescence of nanoparticles, which are dispersed in water droplets in a microfluidic chip. Keywords: photon-upconversion; microfluidic chip; microdroplets; nanoparticles Fulltext is available at external website.
Measuring photon-upconversion luminiscence from droplets in microfluidic chips

UCNPs are lanthanide-doped nanocrystals that can be excited by near-infrared light and emit light of shorter wavelengths. Advantages of UCNPs include multiple and narrow emission bands, negligible ...

Hlaváček, Antonín; Křivánková, Jana; Přikryl, Jan
Ústav analytické chemie, 2018

About project

NRGL provides central access to information on grey literature produced in the Czech Republic in the fields of science, research and education. You can find more information about grey literature and NRGL at service web

Send your suggestions and comments to nusl@techlib.cz

Provider

http://www.techlib.cz

Facebook

Other bases