CNT composite - polishing methods and metalic coating
Thoř, Tomáš; Václavík, Jan; Vápenka, David
2017 - English
This study summarizes R&D tasks done in order to develop technology for polishing and metallic coating of CNT composite for optical and radiofrequency applications. Development was done on two types of material samples:\n- Material for the MIRROR demonstrator\n- Material for the FEEDHORN demonstrator
Keywords:
polishing; cnt composite; metallic coating
Available at various institutes of the ASCR
CNT composite - polishing methods and metalic coating
This study summarizes R&D tasks done in order to develop technology for polishing and metallic coating of CNT composite for optical and radiofrequency applications. Development was done on two types ...
Research report 2013-11-10 Calcite_SS3
Kumpová, Ivana; Vopálenský, Michal; Vavřík, Daniel
2017 - English
Porosity was measured on a irregular sample of calcite, designated Calcite_S43, using the TORATOM device in the Centre of Excellence Telč.
Keywords:
calcite; TORATOM; porosity
Available at various institutes of the ASCR
Research report 2013-11-10 Calcite_SS3
Porosity was measured on a irregular sample of calcite, designated Calcite_S43, using the TORATOM device in the Centre of Excellence Telč.
Research report 2013-11-19 Calcite_S43
Kumpová, Ivana; Vopálenský, Michal; Vavřík, Daniel
2017 - English
Porosity was measured on a irregular sample of calcite, designated\nCalcite_S43, using the TORATOM device in the Centre of Excellence Telč.\n
Keywords:
calcite; TORATOM; measuring
Available at various institutes of the ASCR
Research report 2013-11-19 Calcite_S43
Porosity was measured on a irregular sample of calcite, designated\nCalcite_S43, using the TORATOM device in the Centre of Excellence Telč.\n
Research report 2013-11-19 Calcite_S11
Kumpová, Ivana; Vopálenský, Michal; Vavřík, Daniel
2017 - English
Porosity was measured on a irregular sample of calcite, designated Calcite_S11, using the TORATOM device in the Centre of Excellence Telč.
Keywords:
calcite; TORATOM; measuring
Available at various institutes of the ASCR
Research report 2013-11-19 Calcite_S11
Porosity was measured on a irregular sample of calcite, designated Calcite_S11, using the TORATOM device in the Centre of Excellence Telč.
The Flow of Mixture Vapors in the Vacuum Column K101, Nominal and Reduced Capacity
Říha, Zdeněk
2017 - English
The report contains CFD results and description of the gas mixture flow in the bottom part of the vacuum column K101. There were solved two cases. Both cases had the same geometry. The difference between ones was in quantity of vapors on the inputs. The first case was calculated for the nominal quantity of vapors. The second case was calculated for reduced quantity (60% of nominal quantity) of vapors. Calculated results of above mentioned cases are placed in report´s enclosures 1 and 2.
Keywords:
CFD results; vacuum column; gas mixture flow
Available at various institutes of the ASCR
The Flow of Mixture Vapors in the Vacuum Column K101, Nominal and Reduced Capacity
The report contains CFD results and description of the gas mixture flow in the bottom part of the vacuum column K101. There were solved two cases. Both cases had the same geometry. The difference ...
Cutting experiments with ASJ at 1500 bar
Zeleňák, Michal; Foldyna, Josef; Souček, Kamil; Klichová, Dagmar
2016 - English
The aim of experimental work was to determine cutting condition maximal, middle and fine traverse speeds for selected materials and thicknesses. Materials were cut at pressure 1500 bars and 10% of suspension concentration. Secondary objective is long-term monitoring of nozzles wear using X – Ray CT tomography.
Keywords:
high-speed abrasive suspension jet; cutting; technology
Available at various institutes of the ASCR
Cutting experiments with ASJ at 1500 bar
The aim of experimental work was to determine cutting condition maximal, middle and fine traverse speeds for selected materials and thicknesses. Materials were cut at pressure 1500 bars and 10% of ...
Optical measurements on TR-P-4 cascade
Luxa, Martin; Šimurda, David
2016 - English
Report contains results and analysis of optical measurements (interferometry and schlieren photography) on the on the optimised variant of the hub section of the ultra long rotor blade for the last stage of a large output steam turbine. Internal designation of the cascade is TR-P-4.
Keywords:
hub section; long turbine blade; transonic flow
Available at various institutes of the ASCR
Optical measurements on TR-P-4 cascade
Report contains results and analysis of optical measurements (interferometry and schlieren photography) on the on the optimised variant of the hub section of the ultra long rotor blade for the last ...
Methodology of camera spectral response measurement
Melich, Radek; Václavík, Jan; Žídek, Karel
2016 - English
Spectral response of the camera will be measured using monochromator in conjunction with an integration sphere. Camera without objective will be placed in one port of the integrating sphere and light beam from monochromator will be fed into perpendicular port. Sensor of the camera sensor will be therefore uniformly illuminated by diffused light from monochromator. Proposed FWHM of the monochromator is 15 nm as a trade-off between light intensity provided by monochromator and deformation of spectral characteristic (Picture XY). Diameter of the integrating sphere has to be larger than 100 mm to ensure uniform illumination over sensor area.
Keywords:
Camera spectral response
Available at various institutes of the ASCR
Methodology of camera spectral response measurement
Spectral response of the camera will be measured using monochromator in conjunction with an integration sphere. Camera without objective will be placed in one port of the integrating sphere and light ...
Evaluation of selected parameters of a LIBA2000 glass melt according to ISO 12123.
Václavík, Jan
2016 - English
Measurement of refractive indices of samples, specifically refractive indicies nd, ne and Abbe numbers for spectral lines d and e. Assesment of refractive index variation, internal spectal transmitance and amount of striae in samples.\n
Keywords:
glass melt; ISO 12123; striae; refractive index; inhomogeneity
Available at various institutes of the ASCR
Evaluation of selected parameters of a LIBA2000 glass melt according to ISO 12123.
Measurement of refractive indices of samples, specifically refractive indicies nd, ne and Abbe numbers for spectral lines d and e. Assesment of refractive index variation, internal spectal ...
Device calibration.
Melich, Radek; Václavík, Jan; Žídek, Karel
2016 - English
The device has to be calibrated in absolute terms for its brightness response. This will be facilitated by a combination of an integrating sphere and collimating objective. The emitted total light intensity will be controlled by a reference photodiode inside the integrating sphere.
Keywords:
absolute brightness calibration
Available at various institutes of the ASCR
Device calibration.
The device has to be calibrated in absolute terms for its brightness response. This will be facilitated by a combination of an integrating sphere and collimating objective. The emitted total light ...
NRGL provides central access to information on grey literature produced in the Czech Republic in the fields of science, research and education. You can find more information about grey literature and NRGL at service web
Send your suggestions and comments to nusl@techlib.cz
Provider