Number of found documents: 77
Published from to

Initial Behavior of a Vapor Bubble in a Superheated Liquid
Vejražka, Jiří
2008 - English
The model is based on a simplified law for heat transfer of a growing and moving bubble and on solving the forces acting on this bubble. The model is represented by a system of ordinary differential equations and can be used until the time when bubbles start to wobble. An partially successful (but not convincing) attempt to validate this model by comparison with available experimental data was done. In most cases, the bubble behavior is controlled by a balance of the buoyancy with the added-mass force. In this aspect, the bubble behavior differs considerably from the case of constant-volume bubbles, for which the added-mass force is usually negligible. For the case of spherical bubbles, a simple analytical solutions are provided. Práce prezentuje matematický model pro předvídání růstu a pohybu bubliny páry v přehřáté kapalině. Model je založen na zjednodušených zákonech pro přestup tepla rostoucí a pohybující se bubliny a na řešení bilance sil působících na bublinu. Model je ve tvaru soustavy obyčejných diferenciálních rovnic a může být použit až do okamžiku, kdy tvar bubliny značne oscilovat. Model je srovnán s dostupnými experimentálními daty, se kterými vykazuje částečnou shodu. Ukazuje se, že v případě větších podmínek je pohyb bubliny udán rovnováhou Archimedovy síly se silou přidané hmotnosti. V tomto ohledu je chování bubliny výrazně odlišné od případu bubliny s konstantním objemem, v jejichž případě je síla přidané hmotnosti většinou zanedbatelná. Konečně, v případě kulových bublin bylo nalezeno analytické řešení matematického modelu. Keywords: vapor bubble; differential equations; transfer of bubbles Available at various institutes of the ASCR
Initial Behavior of a Vapor Bubble in a Superheated Liquid

The model is based on a simplified law for heat transfer of a growing and moving bubble and on solving the forces acting on this bubble. The model is represented by a system of ordinary differential ...

Vejražka, Jiří
Ústav chemických procesů, 2008

EDWork I. Software Installation
Wein, Ondřej; Sobolík, Václav; Kiefmann, J.
2008 - English
A guide for installing the software package EDWork, which controls the digital-analog hybrid device EDIK for electrodiffusion measurements. Návod k instalaci softwarového balíku EDWORK, pomocí kterého je řízen digitálně-analogový hybrid, přístroj EDIK sloužící k elektrodifuzním měřením. Keywords: electrodiffusion technique; controlling software; device EDIK Available at various institutes of the ASCR
EDWork I. Software Installation

A guide for installing the software package EDWork, which controls the digital-analog hybrid device EDIK for electrodiffusion measurements....

Wein, Ondřej; Sobolík, Václav; Kiefmann, J.
Ústav chemických procesů, 2008

Theory of Electrodiffusion Friction Probes in Microdisperse Liquids 7. Effect of Longitudinal Diffusion for a Strip Probe
Wein, Ondřej
2008 - English
Full 2D equations of convective diffusion are solved numerically for a finite strip electrodiffusion probe in a stream of microdisperse liquid, for near-to-wall non-linear velocity profiles ranging from constant shear rate flow to ideal slip. The modified Peclet number H, ranging from 0.01 (almost no convection) to 100 (diffusion layer regime), covers all cases of possible experimental relevance. Plné 2D rovnice konvektivní difuze jsou řešeny numericky pro páskové elektrodifuzní čidlo v proudu mikrodisperzní kapaliny, pro přístěnné nelineární rychlostní profily pokrývající oblast od smykového toku po ideální skluz. Modifikované Pecletovo číslo v oblasti od 0,01 (takřka bez konvekce) do 100 (koncentrační mezní vrstva) kompletně pokrývá oblast experimentální relevance. Keywords: microdisperse fluid flow; electrodiffusion flow diagnostics; longitudinal diffusion Available at various institutes of the ASCR
Theory of Electrodiffusion Friction Probes in Microdisperse Liquids 7. Effect of Longitudinal Diffusion for a Strip Probe

Full 2D equations of convective diffusion are solved numerically for a finite strip electrodiffusion probe in a stream of microdisperse liquid, for near-to-wall non-linear velocity profiles ranging ...

Wein, Ondřej
Ústav chemických procesů, 2008

EDWork II. The EDIK Device
Wein, Ondřej; Sobolík, Václav; Kiefmann, J.
2008 - English
A reference book of the digital-analog hybrid EDIK2 for electrodiffusion measurements Návod k instalaci softwarového balíku EDWORK, pomocí kterého je řízen digitálne-analogový hybrid, prístroj EDIK sloužící k elektrodifuzním měřením. Keywords: electrodiffusion technique; device edik; digital-analog hybrid Available at various institutes of the ASCR
EDWork II. The EDIK Device

A reference book of the digital-analog hybrid EDIK2 for electrodiffusion measurements...

Wein, Ondřej; Sobolík, Václav; Kiefmann, J.
Ústav chemických procesů, 2008

Theory of Electrodiffusion Friction Probes in Microdisperse Liquids 6. Effect of Insulating Gaps in DL Approximation
Wein, Ondřej
2007 - English
Insulated insertions between individual segments of direction-sensitive electrodiffusion friction probes attenuate the direction sensitivity. Quantitative study of this effect by Wein and Wichterle (1989) for Newtonian liquids is expanded on the microdisperse liquids, displaying the Apparent Wall Slip, i.e. a non-linear velocity profile close to solid surfaces. Isolační vložky mezi jednotlivými segmenty směrově citlivých elektrodifuzních čidel zeslabují jejich směrovou citlivost. Kvantitativní studie tohoto efektu od Weina a Wichterleho (1989) pro Newtonské kapaliny je rozšířena na mikrodisperzní kapaliny, vykazující zdánlivý skluz při stěně, tj. nelinární rychlostní profil v blízkosti pevných povrchů. Keywords: electrodiffusion diagnostics of flow; apparent slip at wall; direction-sensitive friction Ppobes Available at various institutes of the ASCR
Theory of Electrodiffusion Friction Probes in Microdisperse Liquids 6. Effect of Insulating Gaps in DL Approximation

Insulated insertions between individual segments of direction-sensitive electrodiffusion friction probes attenuate the direction sensitivity. Quantitative study of this effect by Wein and Wichterle ...

Wein, Ondřej
Ústav chemických procesů, 2007

Effect of Insulating Gaps on the Dynamics of Electrodiffusion Friction Probes II. Voltage-step Transient and Impedance.
Wein, Ondřej; Kiefmann, J.; Slezák, Jiří; Tovčigrečko, Valentin
2006 - English
Direction-specific (multi-segment) electrodiffusion (ED) probes were tested and calibrated under dynamic conditions (time-dependent flow, potentiostatic transient). Software package EDIKWORK has been developed within framework of the NI LabVIEW programming system, for an automated control of the ED experiment and and data acquisition (in four working regimes STA, TRA, OSC, VAM). High automated programs under MS EXCEL were prepared for the downstream treatment of excessive series of primary data and calibration of ED probes. Směrově citlivá (vícesegmentová) elektrodifuzní (ED) čidla tření byla testována za dynamických podmínech (časově proměnné proudění kapaliny za podmínek harmonicky superponovaného viskometrického toku, potenciostatický přechodový proces). Pro automatické řízení experimentu a sběr ED dat (ve čtyřech režimech STD, TRA, OSC, VAM) byl vyvinut softwarový balík EDIKWORK v rámci systému NI LabVIEW. Pro interpretaci ED dat a dynamickou kalibraci čidel na základě dostupných teorií neustálené konvektivní difuze (se zahrnutím vlivu isolačních vložek mezi segmenty, vlivu prostorové difuze, a vlivu drsnosti povrchu pracovních elektrod) byly připraveny v MS EXCEL vysoce automatizované programy pro následné zpracování rozsáhlých serií primárních dat. Keywords: dynamics of electrodiffusion probes; multisegment probes; insulating gaps Available at various institutes of the ASCR
Effect of Insulating Gaps on the Dynamics of Electrodiffusion Friction Probes II. Voltage-step Transient and Impedance.

Direction-specific (multi-segment) electrodiffusion (ED) probes were tested and calibrated under dynamic conditions (time-dependent flow, potentiostatic transient). Software package EDIKWORK has been ...

Wein, Ondřej; Kiefmann, J.; Slezák, Jiří; Tovčigrečko, Valentin
Ústav chemických procesů, 2006

Edge Effects in Rotational Viscometry V. Testing Pseudosimilarity for Ideal Couette Sensor.
Wein, Ondřej
2006 - English
The pseudosimilarity concept makes it possible to estimate end-effects in rotational viscometry without using more-parameter models of viscosity function but, on the other hand, it introduces some error. Actual extent of the deviations for an ideal Couette flow between coaxial cylinders is studied for common 2- and 3- parameter models of viscosity function. Koncepce pseudopodobnosti eliminuje nezbytnost práce s více parametrovými modely viskozitní funkce při odhadu koncových efektů. Cenou za tuto výhodu při zpracování primárních dat z rotační viskozimetrie je snížená přesnost. Skutečná míra odchylek pro ideální Couette-ovský tok mezi koaxiálními válci je studována pro některé běžné dvou- a tří- parametrové modely viskozitní funkce. Keywords: pseudosimilarity in rotational viscometry; edge effects; couette flow Available at various institutes of the ASCR
Edge Effects in Rotational Viscometry V. Testing Pseudosimilarity for Ideal Couette Sensor.

The pseudosimilarity concept makes it possible to estimate end-effects in rotational viscometry without using more-parameter models of viscosity function but, on the other hand, it introduces some ...

Wein, Ondřej
Ústav chemických procesů, 2006

Edge Effects in Rotational Viscometry IV. ZZ (Couette) Sensors, No-Slip, Genuine Viscosity Functions.
Wein, Ondřej
2006 - English
Neglect of end effects in Couette rotational viscometry introduces 10-30% error in the estimate of shear stress at spindle surface. Actual deviations depend on the shear-thinning level of a given sample. We tackle the end effect for the standard sensor Z40 DIN according to ISO 3219 by solving the related 2D boundary-value problem for a class of shear-thinning viscosity functions. Pseudosimilarity method of treating the primary data leaves an error in shear stresses about 0.5%. Further reduction of the errors needs a full numerical simulation for each point of primary data, based on a suitable wide-range representation of the viscosity function. To support high accuracy of torque calibrations, the effect of inertia on torque for Newtonian liquids in standard sensor Z40 DIN at Re < 500 is calculated using the FLUENT 6.2 commercial software. Zanedbání koncových efektů v Couette-ovské rotační viskozimetrii přináší 10-30% chybu v odhadu smykového napětí na povrchu vřetene. Skutečné odchylky závisí na míře pseudoplasticity daného vzorku. Studovány jsou koncové efekty pro standardní senzor Z40 DIN podle ISO 3219 řešením odpovídající dvourozměrné okrajové úlohy pro třídu pseudoplastických viskozitních funkcí. Použití metody pseudosimilarity pro primární data dává ve smykovém napětí chybu okolo 0,5%. Pro další snížení chyby by byla nutná plná numerická simulace každého bodu primárních dat, založená na vhodné reprezentaci viskozitní funkce v širokém rozsahu argumentu. Výpočty, sloužící k podpoře přesné momentové kalibrace s Newtonskou kapalinou v standardním senzoru Z40 DIN při Re < 500, byly provedeny s použitím komerčního software FLUENT 6.2. Keywords: rotational couette viscometry; shear-thinning fluids; end effects Available at various institutes of the ASCR
Edge Effects in Rotational Viscometry IV. ZZ (Couette) Sensors, No-Slip, Genuine Viscosity Functions.

Neglect of end effects in Couette rotational viscometry introduces 10-30% error in the estimate of shear stress at spindle surface. Actual deviations depend on the shear-thinning level of a given ...

Wein, Ondřej
Ústav chemických procesů, 2006

Effect of Insulating Gaps on the Dynamics of Electrodiffusion Friction Probes I. A laboratory Unit for Calibration and testing of the Multisegment Electrodiffusion Probes.
Wein, Ondřej; Kiefmann, J.; Slezák, Jiří; Tovčigrečko, Valentin
2006 - English
A PC-driven multi-channel ED interface EDIK has been designed and tested in a project of dynamical calibration of multi-segment ED probes. Due to a specific approach to the calibration, this PC-driven device ensures accuracy about 0.1 mV in the supplied polarization voltage and about 0.1% from the range selected, with ranges 10-1?A : 10+4?A. A user-friendly software EDIKWork has been developed for the ED process control, data sampling and analysis within the environment of the NI LabVIEW. A hydraulic unit for generating parallel-superposed oscillatory viscometric flow (based on a commercial servomotor solution by YASKAWA) has been designed and used for dynamical calibration of 2-segment (sandwich type) and 3-segment (direction-specific) ED probes. Vícekanálové ED-rozhraní řízené počitačem bylo vybudováno a testováno v projektu dynamické kalibrace vícesegmentových ED čidel. Díky specifickému způsobu kalibrace má tento počitačem řízený přístroj přesnost 0.1 mV polarizačního napětí a cca 0.1% ve vybraném rozsahu 0.1 - 10000 mkA. Pro řízení experimentu a sběr dat byl vyvinut software EDIKWork v prostředí NI LabVIEW. Hydraulická jednotka pro generování paralelního superponovaného oscilačního viskometrického toku (založená na komerčním servomotoru YASKAWA) byla vyrobena a použita pro dynamickou kalibraci dvousegmentových (sendvičových) a třísegmentových (směrově citlivých) ED čidel. Keywords: multisegment electrodiffusion probes; viscometric Ffow; laboratory unit for calibration Available at various institutes of the ASCR
Effect of Insulating Gaps on the Dynamics of Electrodiffusion Friction Probes I. A laboratory Unit for Calibration and testing of the Multisegment Electrodiffusion Probes.

A PC-driven multi-channel ED interface EDIK has been designed and tested in a project of dynamical calibration of multi-segment ED probes. Due to a specific approach to the calibration, this PC-driven ...

Wein, Ondřej; Kiefmann, J.; Slezák, Jiří; Tovčigrečko, Valentin
Ústav chemických procesů, 2006

Electrodiffusion Diagnostics of Flow. Transient Convective Diffusion to a Circular Sink at Low Peclet Numbers
Wein, Ondřej
2005 - English
Autocalibration electrodiffusion (ED) wall friction measurements at low Peclet numbers are improved both theoretically and experimentally. Existing theories are united to a simple semiempirical description of the voltage-step transient at non-ideal circular probes. The final transport model of the voltage-step transient for nearly-circular probes is implemented to the PC software EDSWork PR10 for treating the laboratory transient data. A special ED cell was designed for the voltage-step transient ED experiments under a well-controlled steady viscometric flow. The transient ED measurements with a series of aqueous glycerol solutions cover rather broad interval of the convective-diffusion regime and represent an experimental material suitable for a careful calibration of the probes and for a check of the related unsteady mass-transfer theory. Autokalibrační ED diagnostika tření při stěně při nízkých Pe je zlepšena teoreticky i experimentálně. Stávající teorie dílčích procesů jsou shrnuty do jednoduchého semiempirického popisu potenciostatické přechodové charaktyeristiky pro kruhová čidla s neideální geometrií. Konečný transportní model je implementován do PC softwaru „EDSWork PR10“ pro zpracování ůaboratorních přechodovýchdat. Byla zkonstruována speciální ED cela s ustáleným viskometrickým tokem. Přechodová ED měření s řadou vodných roztoků glycerinu pokrývají dosti široký interval režimů konvektivní difuse a representují dostatečný experimentální materiál pro pečlivou kalibraci čidel a pro ověření příslušné teorie neustálného sdíelní hmoty. Keywords: electrodiffusion friction probes; low Peclet convective diffusion; voltage-step transient Available at various institutes of the ASCR
Electrodiffusion Diagnostics of Flow. Transient Convective Diffusion to a Circular Sink at Low Peclet Numbers

Autocalibration electrodiffusion (ED) wall friction measurements at low Peclet numbers are improved both theoretically and experimentally. Existing theories are united to a simple semiempirical ...

Wein, Ondřej
Ústav chemických procesů, 2005