Selection process of an observation objective with respect to minimal glare level
Melich, Radek; Václavík, Jan; Žídek, Karel
2016 - English
An observation objective (OO) that will image the projection screen on the camera detector is necessary to choose in a such a way that its glare performance is traced. This objective feature is not documented by an objective supplier, therefore we design a procedure that enable us to relatively compare the objective between each other.
Keywords:
objective glare
Available at various institutes of the ASCR
Selection process of an observation objective with respect to minimal glare level
An observation objective (OO) that will image the projection screen on the camera detector is necessary to choose in a such a way that its glare performance is traced. This objective feature is not ...
Measurement attest of M0 - STM1
Lédl, Vít; Melich, Radek; Vít, Tomáš
2016 - English
Scope of the document is to provide required test results as demanded in order No 23/14 Attachment – paragraph 6 – bullet 7.
Keywords:
METIS mirror Mé - STM
Available at various institutes of the ASCR
Measurement attest of M0 - STM1
Scope of the document is to provide required test results as demanded in order No 23/14 Attachment – paragraph 6 – bullet 7.
NEOSTEL Fly-Eye Optics Alignment Aid System (AAS) - design
Budasz, Jiří; Lédl, Vít; Pleštil, Jan; Steiger, Kateřina; Steiger, Lukáš; Václavík, Jan; Veselý, Martin; Vít, T.
2016 - English
The aim of this document is to describe the design of the Fly-Eye Optics Alignment Aid System.
Keywords:
laser source; Alignment; References; FEM analysis
Available at various institutes of the ASCR
NEOSTEL Fly-Eye Optics Alignment Aid System (AAS) - design
The aim of this document is to describe the design of the Fly-Eye Optics Alignment Aid System.
Measurement on valve IV
Šimurda, David; Hála, Jindřich; Luxa, Martin
2016 - English
Report contains results and evaluation of pneumatic measurements conducted on the overloading valve system.
Keywords:
steam valve; experimental aerodynamics; pneumatic measurements
Available at various institutes of the ASCR
Measurement on valve IV
Report contains results and evaluation of pneumatic measurements conducted on the overloading valve system.
Micro-Raman analysis of samples irradiated at the FLASH facility in Summer 2014 (Report v1-31_05_2016)
Toufarová, Martina; Hájková, Věra; Chalupský, Jaromír; Juha, Libor
2016 - English
The goal of micro-Raman measurements was to indicate a presence of the carbon black grown in the FEL-illuminated areas on the sample surface. Twelve samples have been investigated and results have been reported to the X-ray Optics Group at the University of Twente.
Keywords:
radiation damage; carbon black; free-electron laser; soft x-rays; Raman spectroscopy
Available at various institutes of the ASCR
Micro-Raman analysis of samples irradiated at the FLASH facility in Summer 2014 (Report v1-31_05_2016)
The goal of micro-Raman measurements was to indicate a presence of the carbon black grown in the FEL-illuminated areas on the sample surface. Twelve samples have been investigated and results have ...
METIS mirror M0 FM
Lédl, Vít; Melich, Radek; Vít, Tomáš
2016 - English
Scope of the document is to provide required test results with respect to the structure of M0 mirror, FM version. The mirror has a unique numbering M0-C19-22.
Keywords:
METSI M0 FM mirror
Available at various institutes of the ASCR
METIS mirror M0 FM
Scope of the document is to provide required test results with respect to the structure of M0 mirror, FM version. The mirror has a unique numbering M0-C19-22.
On Nominal Automata as Models of Java-like Object-Oriented Programs
Suzuki, Tomoyuki
2016 - English
In this paper, we proposed a model of Java-like object-oriented programs as nominal automata and a simple method invocation checker.
Available on request at various institutes of the ASCR
On Nominal Automata as Models of Java-like Object-Oriented Programs
In this paper, we proposed a model of Java-like object-oriented programs as nominal automata and a simple method invocation checker.
NEOSTEL Collimator Realization Detailed Optical Design.
Melich, Radek; Steiger, Lukáš; Václavík, Jan; Vít, T.
2016 - English
The aim of this document is to describe the optical design of the Alignment Collimator for the NEOSTEL telescope. The document describes proposed optical and mechanical design. It consists of several parts:\n• Optical design and its tolerance analysis\n• Ghost image analysis\n• Stray light analysis\n• Mechanical design and FEM analysis
Keywords:
Alignment Collimator; NEOSTEL; Optical design
Available on request at various institutes of the ASCR
NEOSTEL Collimator Realization Detailed Optical Design.
The aim of this document is to describe the optical design of the Alignment Collimator for the NEOSTEL telescope. The document describes proposed optical and mechanical design. It consists of several ...
Optical measurements on TR-U-7 cascade
Luxa, Martin; Šimurda, David
2016 - English
Report contains results and analysis of optical measurements (interferometry and schlieren photography) on the variant of the tip section of the 60" (1525) long rotor blade for the last stage of a large output steam turbine. Internal designation of the cascade is TR-U-7. Measurements were performed in the test section with small flow turning.
Keywords:
tip section; long turbine blade; transonic flow
Available at various institutes of the ASCR
Optical measurements on TR-U-7 cascade
Report contains results and analysis of optical measurements (interferometry and schlieren photography) on the variant of the tip section of the 60" (1525) long rotor blade for the last stage of a ...
Measurement of camera spectral response
Melich, Radek; Václavík, Jan; Žídek, Karel
2016 - English
Spectral response of the camera will be measured using monochromator in conjunction with an integration sphere. Camera without objective will be placed in one port of the integrating sphere and light beam from monochromator will be fed into perpendicular port. Sensor of the camera sensor will be therefore uniformly illuminated by diffused light from monochromator. Proposed FWHM of the monochromator is 15 nm as a trade-off between light intensity provided by monochromator and deformation of spectral characteristic (Picture XY). Diameter of the integrating sphere has to be larger than 100 mm to ensure uniform illumination over sensor area.
Keywords:
Camera spectral response
Available at various institutes of the ASCR
Measurement of camera spectral response
Spectral response of the camera will be measured using monochromator in conjunction with an integration sphere. Camera without objective will be placed in one port of the integrating sphere and light ...