Number of found documents: 164
Published from to

Micro-electromembrane extraction across multiple aqueous and organic phases for selective pretreatment of raw biological samples
Kubáň, Pavel; Boček, Petr; Seip, K. F.; Gjelstad, A.; Pedersen-Bjergaard, S.
2016 - English
Micro-electromembrane extraction (μ-EME) across multiple aqueous and organic\nsolutions was developed for selective extractions of various analytes from untreated\nbiological samples. The novel approach requires μL volumes of samples and organic\nsolvents, which form consecutive immiscible plugs in a transparent polymeric capillary\nand the extraction process is accelerated by application of d.c. voltage. Number of the\nplugs, their composition, volume and sequence in the extraction capillary can be chosen\nspecifically for each particular application and high variability and selectivity of the\nextraction process can be achieved. In this contribution, we demonstrate suitability of\na five-phase μ-EME system for simultaneous extractions of cations and anions from\nurine and for selective extractions of basic analytes based on their acid-base strength\nfrom plasma. Keywords: micro-electromembrane extraction; sample pretreatment techniques; biological samples Available in digital repository of the ASCR
Micro-electromembrane extraction across multiple aqueous and organic phases for selective pretreatment of raw biological samples

Micro-electromembrane extraction (μ-EME) across multiple aqueous and organic\nsolutions was developed for selective extractions of various analytes from untreated\nbiological samples. The novel ...

Kubáň, Pavel; Boček, Petr; Seip, K. F.; Gjelstad, A.; Pedersen-Bjergaard, S.
Ústav analytické chemie, 2016

Characterization of FRET sensor
Datinská, Vladimíra; Klepárník, Karel; Belšánová, B.; Minárik, M.; Foret, František
2016 - English
In this study, we present characterization of sensor based on Fӧrster resonance energy\ntransfer (FRET). The sensor is composed of ssDNA chain attached to a laboratory\nsynthesized quantum dot (QD). A complementary chain of a sample is labeled by a\nluminescent dye. When the dsDNA hybrid is formed, the energy from the QD (donor)\nis transferred to the dye (acceptor) and FRET is observed as a decrease of QD\nluminescence emission intensity and an increase of dye luminescence emission\nintensity. Keywords: FRET sensor; Fӧrster resonance energy transfer; quantum dot Available in digital repository of the ASCR
Characterization of FRET sensor

In this study, we present characterization of sensor based on Fӧrster resonance energy\ntransfer (FRET). The sensor is composed of ssDNA chain attached to a laboratory\nsynthesized quantum dot (QD). A ...

Datinská, Vladimíra; Klepárník, Karel; Belšánová, B.; Minárik, M.; Foret, František
Ústav analytické chemie, 2016

Microfluidic device for cell counting and characterization
Václavek, Tomáš; Křenková, Jana; Foret, František
2016 - English
Integration of cell counting unit is an important step in developing of microfluidic\ndevice for cellular analysis. Here we present a microfluidic device for cell counting\nbased on resistive pulse sensing. Keywords: microfluidic devices; microfluidic chip; cellular analysis Available in digital repository of the ASCR
Microfluidic device for cell counting and characterization

Integration of cell counting unit is an important step in developing of microfluidic\ndevice for cellular analysis. Here we present a microfluidic device for cell counting\nbased on resistive pulse ...

Václavek, Tomáš; Křenková, Jana; Foret, František
Ústav analytické chemie, 2016

Organic markers and compounds in PM1 aerosol in small town near Prague (Czech Republic) in winter 2016
Křůmal, Kamil; Mikuška, Pavel; Coufalík, Pavel; Večeřa, Zbyněk
2016 - English
Contribution summarizes the concentrations of monosaccharide anhydrides, resin\nacids, methoxyphenols, monosaccharides, disaccharides, sugar alcohols, alkanes,\nhopanes, steranes and polycyclic aromatic hydrocarbons in PM1 aerosols in small town\nKladno-Švermov in winter. According to concentrations of organic markers, the\nidentification of emission sources in Kladno-Švermov is discussed. Keywords: organic markers; PM1 aerosol; combustion of biomass; aerosols collected Available in digital repository of the ASCR
Organic markers and compounds in PM1 aerosol in small town near Prague (Czech Republic) in winter 2016

Contribution summarizes the concentrations of monosaccharide anhydrides, resin\nacids, methoxyphenols, monosaccharides, disaccharides, sugar alcohols, alkanes,\nhopanes, steranes and polycyclic ...

Křůmal, Kamil; Mikuška, Pavel; Coufalík, Pavel; Večeřa, Zbyněk
Ústav analytické chemie, 2016

Capillary electrophoresis with contactless conductivity detection for rapid determination of meldonium in urine
Šlampová, Andrea; Kubáň, Pavel
2016 - English
A simple, rapid and cheap capillary electrophoresis-capacitively coupled contactless\nconductivity detection (CE-C4D) method for determination of meldonium (MEL) in\nurine samples was developed. Sample pretreatment was minimized to dilution of urine\nsamples with DI water and MEL was determined by CE-C4D in background electrolyte\nconsisting of 2 M acetic acid (pH 2.3) in ng mL−1 to mg mL−1 concentration range.\nSample-to-sample analysis time was less than 4 min, limit of detection and\nquantification was 0.015 and 0.05 μg mL−1, respectively, and the method showed\nexcellent linearity (r2 ≥ 0.9998), recovery (97.6–99.9%) and intraday as well as interday\nrepeatability (RSD ≤ 4.7%). Keywords: meldonium; capillary electrophoresis-capacitively coupled contactless conductivity detection; urine Available in digital repository of the ASCR
Capillary electrophoresis with contactless conductivity detection for rapid determination of meldonium in urine

A simple, rapid and cheap capillary electrophoresis-capacitively coupled contactless\nconductivity detection (CE-C4D) method for determination of meldonium (MEL) in\nurine samples was developed. ...

Šlampová, Andrea; Kubáň, Pavel
Ústav analytické chemie, 2016

Prototyping of a simple device for parallel dot blotting using CNC machining
Novotný, Jakub; Svobodová, Z.; Bílková, Z.; Foret, František
2016 - English
Computer numerical control (CNC) machining has been tested for rapid prototyping of\na new design of a dot-blotting device suitable for parallel testing of antibodies. The\ndevice, machined from polycarbonate, was prepared using an inexpensive computer\ncontrolled CNC router. Keywords: CNC machines; dot-blotters; CNC router Available in digital repository of the ASCR
Prototyping of a simple device for parallel dot blotting using CNC machining

Computer numerical control (CNC) machining has been tested for rapid prototyping of\na new design of a dot-blotting device suitable for parallel testing of antibodies. The\ndevice, machined from ...

Novotný, Jakub; Svobodová, Z.; Bílková, Z.; Foret, František
Ústav analytické chemie, 2016

Evaluation of stationary phases for HPLC based on nanofibers
Čmelík, Richard; Foret, František
2016 - English
In this study, the performance parameters were compared for the set of chromatographic columns filled with polyacrylonitrile nanofibers processed in the different manner. The advantages and challenges of the novel fillings were discussed. Keywords: nanofiber; HPLC; stationary phase Available in digital repository of the ASCR
Evaluation of stationary phases for HPLC based on nanofibers

In this study, the performance parameters were compared for the set of chromatographic columns filled with polyacrylonitrile nanofibers processed in the different manner. The advantages and challenges ...

Čmelík, Richard; Foret, František
Ústav analytické chemie, 2016

Geochemistry of Cenozoic volcanic rocks of the Faroe Islands with a focus on their ultra-trace contents of Hg
Šišková, P.; Krmíček, Lukáš; Coufalík, Pavel
2016 - English
According to geophysical research performed in the eastern part of the North Atlantic, many authors inferred that the basalt flows on the Faroe Islands overlie a continental metamorphic basement supposedly of Precambrian age. With respect to this, we focused our study on determination of ultratrace mercury contents by means of atomic absorption spectrometry to test this hypothesis. Mercury contents in basalts seem to be a sensitive tool for distinguishing between the basalts not affected by interaction with the continental crust and the basalts enclosing crustal xenoliths. Contents of Hg show great variability between samples even within the same formation. We presume that high concentrations of Hg in some samples are related to stagnation of individual pulses of parent magma in the continental crust below the Faroe Islands. Keywords: Faroe Islands; tholeiitic basalt; mercury content; continental crust Available in digital repository of the ASCR
Geochemistry of Cenozoic volcanic rocks of the Faroe Islands with a focus on their ultra-trace contents of Hg

According to geophysical research performed in the eastern part of the North Atlantic, many authors inferred that the basalt flows on the Faroe Islands overlie a continental metamorphic basement ...

Šišková, P.; Krmíček, Lukáš; Coufalík, Pavel
Ústav analytické chemie, 2016

Concentration of atomic hydrogen measured in a heated atomizer by two-photon absorption laser-induced fluorescence
Dvořák, P.; Talába, M.; Dědina, Jiří; Kratzer, Jan; Obrusník, A.
2016 - English
Concentration of free hydrogen atoms was measured by the two-photon absorption laser-induced fluoresence (TALIF) in an externally heated atomizer in a mixture of argon, hydrogen and oxygen at atmospheric pressure. The atomic hydrogen concentration in the order 10^22 m^-3 was found in the region around the flame. Keywords: TALIF; quartz tube atomizer; hydrogen measurement Available in digital repository of the ASCR
Concentration of atomic hydrogen measured in a heated atomizer by two-photon absorption laser-induced fluorescence

Concentration of free hydrogen atoms was measured by the two-photon absorption laser-induced fluoresence (TALIF) in an externally heated atomizer in a mixture of argon, hydrogen and oxygen at ...

Dvořák, P.; Talába, M.; Dědina, Jiří; Kratzer, Jan; Obrusník, A.
Ústav analytické chemie, 2016

Arsenic speciation by hydride generation coupled with atomic fluorescence spectrometry
Marschner, Karel; Musil, Stanislav; Rychlovský, P.; Dědina, Jiří
2016 - English
Post-column hydride generation for arsenic speciation was used and the demethylation of Arsenic species during hydride generation was investigated. Keywords: arsenic speciation; demethylation; hydride generation Available in digital repository of the ASCR
Arsenic speciation by hydride generation coupled with atomic fluorescence spectrometry

Post-column hydride generation for arsenic speciation was used and the demethylation of Arsenic species during hydride generation was investigated.

Marschner, Karel; Musil, Stanislav; Rychlovský, P.; Dědina, Jiří
Ústav analytické chemie, 2016

About project

NRGL provides central access to information on grey literature produced in the Czech Republic in the fields of science, research and education. You can find more information about grey literature and NRGL at service web

Send your suggestions and comments to nusl@techlib.cz

Provider

http://www.techlib.cz

Facebook

Other bases