Effect of Insulating Gaps on the Dynamics of Electrodiffusion Friction Probes I. A laboratory Unit for Calibration and testing of the Multisegment Electrodiffusion Probes.
Wein, Ondřej; Kiefmann, J.; Slezák, Jiří; Tovčigrečko, Valentin
2006 - anglický
A PC-driven multi-channel ED interface EDIK has been designed and tested in a project of dynamical calibration of multi-segment ED probes. Due to a specific approach to the calibration, this PC-driven device ensures accuracy about 0.1 mV in the supplied polarization voltage and about 0.1% from the range selected, with ranges 10-1?A : 10+4?A. A user-friendly software EDIKWork has been developed for the ED process control, data sampling and analysis within the environment of the NI LabVIEW. A hydraulic unit for generating parallel-superposed oscillatory viscometric flow (based on a commercial servomotor solution by YASKAWA) has been designed and used for dynamical calibration of 2-segment (sandwich type) and 3-segment (direction-specific) ED probes. Vícekanálové ED-rozhraní řízené počitačem bylo vybudováno a testováno v projektu dynamické kalibrace vícesegmentových ED čidel. Díky specifickému způsobu kalibrace má tento počitačem řízený přístroj přesnost 0.1 mV polarizačního napětí a cca 0.1% ve vybraném rozsahu 0.1 - 10000 mkA. Pro řízení experimentu a sběr dat byl vyvinut software EDIKWork v prostředí NI LabVIEW. Hydraulická jednotka pro generování paralelního superponovaného oscilačního viskometrického toku (založená na komerčním servomotoru YASKAWA) byla vyrobena a použita pro dynamickou kalibraci dvousegmentových (sendvičových) a třísegmentových (směrově citlivých) ED čidel. Klíčová slova: multisegment electrodiffusion probes; viscometric Ffow; laboratory unit for calibration Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Effect of Insulating Gaps on the Dynamics of Electrodiffusion Friction Probes I. A laboratory Unit for Calibration and testing of the Multisegment Electrodiffusion Probes.

A PC-driven multi-channel ED interface EDIK has been designed and tested in a project of dynamical calibration of multi-segment ED probes. Due to a specific approach to the calibration, this PC-driven ...

Wein, Ondřej; Kiefmann, J.; Slezák, Jiří; Tovčigrečko, Valentin
Ústav chemických procesů, 2006

Electrodiffusion Diagnostics of Flow. Transient Convective Diffusion to a Circular Sink at Low Peclet Numbers
Wein, Ondřej
2005 - anglický
Autocalibration electrodiffusion (ED) wall friction measurements at low Peclet numbers are improved both theoretically and experimentally. Existing theories are united to a simple semiempirical description of the voltage-step transient at non-ideal circular probes. The final transport model of the voltage-step transient for nearly-circular probes is implemented to the PC software EDSWork PR10 for treating the laboratory transient data. A special ED cell was designed for the voltage-step transient ED experiments under a well-controlled steady viscometric flow. The transient ED measurements with a series of aqueous glycerol solutions cover rather broad interval of the convective-diffusion regime and represent an experimental material suitable for a careful calibration of the probes and for a check of the related unsteady mass-transfer theory. Autokalibrační ED diagnostika tření při stěně při nízkých Pe je zlepšena teoreticky i experimentálně. Stávající teorie dílčích procesů jsou shrnuty do jednoduchého semiempirického popisu potenciostatické přechodové charaktyeristiky pro kruhová čidla s neideální geometrií. Konečný transportní model je implementován do PC softwaru „EDSWork PR10“ pro zpracování ůaboratorních přechodovýchdat. Byla zkonstruována speciální ED cela s ustáleným viskometrickým tokem. Přechodová ED měření s řadou vodných roztoků glycerinu pokrývají dosti široký interval režimů konvektivní difuse a representují dostatečný experimentální materiál pro pečlivou kalibraci čidel a pro ověření příslušné teorie neustálného sdíelní hmoty. Klíčová slova: electrodiffusion friction probes; low Peclet convective diffusion; voltage-step transient Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Electrodiffusion Diagnostics of Flow. Transient Convective Diffusion to a Circular Sink at Low Peclet Numbers

Autocalibration electrodiffusion (ED) wall friction measurements at low Peclet numbers are improved both theoretically and experimentally. Existing theories are united to a simple semiempirical ...

Wein, Ondřej
Ústav chemických procesů, 2005

Edge Effects in Rotational Viscometry III. ZZ and KK Sensors, Total Slip Pseudosimilarity
Wein, Ondřej
2005 - anglický
The edge effects in AWS rotational viscometry are studied for materials, displaying the total slip at walls, i.e. negligible effect of the bulk shear flow. The found analytic asymptotes correspond to two asymptotic flow behaviour – for Newtonian liquids and ideal plastic materials. The explicit formulas on the edge-effect correction cL for this constitutionally extreme case are given for the ZZ40 according to ISO 3219 (1994) standard and the novel KK35/23 configuration of our own design. Hranové efekty v rotační viskometrie se zahrnutím zdánlivého skluzu při stěně (AWS) jsou teoreticky studovány pro materiály vykazující totální skluz, tj. zanedbatelný příspěvek objemového střihového toku. Nalezené analytické asymptoty odpovídají dvěma typům asymptotického tokového chování – pro Newtonské kapaliny a pro ideálně plastické materiály. Udány jsou explicitní vztahy pro hranové korekce, cL, pro tyto extrémní konstitutivní případy pro viskozimetry ZZ40 podle normy ISO 3219 (1994) a pro nový viskozimetr KK35/23 podle naší vlastní konstrukce. Klíčová slova: slip at walls; rotational viscometry; edge effects Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Edge Effects in Rotational Viscometry III. ZZ and KK Sensors, Total Slip Pseudosimilarity

The edge effects in AWS rotational viscometry are studied for materials, displaying the total slip at walls, i.e. negligible effect of the bulk shear flow. The found analytic asymptotes correspond to ...

Wein, Ondřej
Ústav chemických procesů, 2005

Edge Effects in Rotational Viscometry II. ZZ (Couette) and KK (Coaxial Morse Cones) Sensors, No-slip Pseudosimilarity
Wein, Ondřej
2004 - anglický
This report is actually deals with corrections of edge effects for a wide spectrum of rotational viscometers with the cylinder-cylinder measuring sections. Tato zpráva udává korekce na hranové efekty pro široké spektrum rotačních viskozimetrů s měřicí sekcí válec-válec. Klíčová slova: rotational viscometry; edge effects; newtonian media Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Edge Effects in Rotational Viscometry II. ZZ (Couette) and KK (Coaxial Morse Cones) Sensors, No-slip Pseudosimilarity

This report is actually deals with corrections of edge effects for a wide spectrum of rotational viscometers with the cylinder-cylinder measuring sections....

Wein, Ondřej
Ústav chemických procesů, 2004

Edge Effects in Rotational Viscometry. I. Cylinder - Cylinder (Couette) System, Newtonian Media
Wein, Ondřej; Večeř, Marek
2004 - anglický
Exact calibration factors for a series of commercially available rotational viscometers are determined by solving the related elliptic boundary-value problem for the rotational flow of Newtonian media under zero Reynolds number (creeping flow approximation). In particular, the edge-effect correction for the Z40 DIN sensor (coaxial cylinders) should be 1.085 instead of incorrect 1.100, given in the related international standard ISO 3219 (Coaxial cylinders for liquids of medium viscosity). The edge-effect correction was determined also for a new KK sensor (coaxial Morse cones) in dependence of the adjustable gap thickness. Přesné kalibrační konstanty u řady komerčně vyráběných viskozimetrů jsou stanoveny řešením odpovídajících okrajových úloh pro rotační tok newtonských kapalin s Reynoldsovým číslem nižším než nula (aproximace toku). Korekce na hranové efekty pro sensor Z40 DIN (koaxiální válce) by však místo nesprávné hodnoty 1.000 (uvedené v normě ISO 3219 (koaxiální válce pro kapaliny se střední viskozitou) měla být 1.085. Korekce hranových efektů byla určena také pro nový KK senzor (koaxiální Morse kužel). Klíčová slova: rotational viscometry; newtonian media; edge correction Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Edge Effects in Rotational Viscometry. I. Cylinder - Cylinder (Couette) System, Newtonian Media

Exact calibration factors for a series of commercially available rotational viscometers are determined by solving the related elliptic boundary-value problem for the rotational flow of Newtonian media ...

Wein, Ondřej; Večeř, Marek
Ústav chemických procesů, 2004

Rotational Viscometry under Presence of Apparent Slip at Walls. VII. Torque and axial thrust in parallel-plate viscometer
Wein, Ondřej
2003 - anglický
An exact theory of the viscometric flow in the parallel-plate rheometer is analyzed numerically for the microdisperse liquids displaying apparent wall slip effect. Klíčová slova: viscometry; normal stresses; apparent wall slip Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Rotational Viscometry under Presence of Apparent Slip at Walls. VII. Torque and axial thrust in parallel-plate viscometer

An exact theory of the viscometric flow in the parallel-plate rheometer is analyzed numerically for the microdisperse liquids displaying apparent wall slip effect.

Wein, Ondřej
Ústav chemických procesů, 2003

Rotational Viscometry under Presence of Apparent Slip at Walls VI. Basic Theory of ZZ, PP, KP, and KK Sensors (for VSWORK PC package under MS Windows)
Wein, Ondřej; Večeř, Marek
2003 - anglický
The theory of viscometric flow under apparent wall slip efefct is outlined. The working formulas for treating primary data of rotational viscometry are given. Klíčová slova: slip; viscometry Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Rotational Viscometry under Presence of Apparent Slip at Walls VI. Basic Theory of ZZ, PP, KP, and KK Sensors (for VSWORK PC package under MS Windows)

The theory of viscometric flow under apparent wall slip efefct is outlined. The working formulas for treating primary data of rotational viscometry are given.

Wein, Ondřej; Večeř, Marek
Ústav chemických procesů, 2003

Electrodiffusion Diagnostics of Flow. Potentiostatic Transient under AWS Conditions
Wein, Ondřej
2003 - anglický
The initial period of this transient does not depend on the flow conditions. It gives the estimate of the complex nFcAD Klíčová slova: electrodiffusion flow diagnostic; wall slip Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Electrodiffusion Diagnostics of Flow. Potentiostatic Transient under AWS Conditions

The initial period of this transient does not depend on the flow conditions. It gives the estimate of the complex nFcAD

Wein, Ondřej
Ústav chemických procesů, 2003

Behavior of Various Separators in Spouted Bed Electrowinning of Cooper
Jiřičný, Vladimír
2002 - anglický
The electrowinning cell of laboratory scale has been tested with various separators. Lifetime and conditions of dendrite formation have been determined for various separators in extended experimental study where effect of operation conditions as current density, temperature, electrolyte composition and impurities have been investigated. The copper deposition was used as a model system. Klíčová slova: metal electrowinning; 3D electrode; copper Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Behavior of Various Separators in Spouted Bed Electrowinning of Cooper

The electrowinning cell of laboratory scale has been tested with various separators. Lifetime and conditions of dendrite formation have been determined for various separators in extended experimental ...

Jiřičný, Vladimír
Ústav chemických procesů, 2002

Calibration and Testing of Laboratory Electrolyser with Spouted Bed Cathode
Jiřičný, Vladimír
2002 - anglický
The electrowinning cell for metal deposition has been design, manufactured and tested. The laboratory size cell enable to be operated as a conventional electrolyser with slab-slab electrodes as well as un- or divided electrolyser with 3D cathode and variable thickness of cathode compartment. The calibration measurements are comparisons among various arrangements of the cell with respect to operation variables as temperature, electrolyte composition, current density, particle size and kind of separator. The copper deposition was used as a model system. Klíčová slova: lab cell; slab-slab electrodes; operational variables Plné texty jsou dostupné na jednotlivých ústavech Akademie věd ČR.
Calibration and Testing of Laboratory Electrolyser with Spouted Bed Cathode

The electrowinning cell for metal deposition has been design, manufactured and tested. The laboratory size cell enable to be operated as a conventional electrolyser with slab-slab electrodes as well ...

Jiřičný, Vladimír
Ústav chemických procesů, 2002