SMV-2017-743: Preparation, testing and delivery of isoelectric point standards
Čmelík, Richard
2017 - English
The project continues long-term cooperation of both participants. The low-molecular mass pI markers were synthesized and examined with aim to fill up and deliver the previously described compounds.
Keywords:
Isoelectric focusing; pI markers; aminomethylphenols
Available on request at various institutes of the ASCR
SMV-2017-743: Preparation, testing and delivery of isoelectric point standards
The project continues long-term cooperation of both participants. The low-molecular mass pI markers were synthesized and examined with aim to fill up and deliver the previously described compounds.
SMV-2017-706: Tests of apparatus for determination of 3H and 14C in air
Večeřa, Zbyněk
2017 - Czech
Testing of ”V3H14C” apparatus designed for 3H and 14C sampling from the air. The samples are captured into sorbents, silica gel for 3H (THO, T2O), and sodium hydroxide for 14C (14CO2) that are subsequently in laboratory analyzed for quantification of radioactive emissions of 3H and 14C from nuclear power plants e.g. Testování a vývoj zařízení řady ”V3H14C”, která jsou určena k odběru vzorků 3H a 14C ze vzduchu. Vzorky se zachycují do sorbentů, sorbentem pro 3H (THO, T2O) je silikagel, sorbentem pro 14C (14CO2) je vodný roztok 3M hydroxidu sodného. Získané vzorky jsou určeny k následné laboratorní analýze. Analýzou zjištěné hodnoty aktivit odebraných vzorků slouží ke stanovení bilance vypouštěného 3H a 14C např. z jaderných zařízení.
Keywords:
testing; air; radioactive emissions
Available at various institutes of the ASCR
SMV-2017-706: Tests of apparatus for determination of 3H and 14C in air
Testing of ”V3H14C” apparatus designed for 3H and 14C sampling from the air. The samples are captured into sorbents, silica gel for 3H (THO, T2O), and sodium hydroxide for 14C (14CO2) that are ...
SMV-2017-732: Preparation, testing and delivery of isoelectric point standards
Čmelík, Richard
2017 - English
The project continues long-term cooperation of both participants. The low-molecular mass pI markers were synthesized and examined with aim to fill up and deliver the previously described compounds.
Keywords:
Isoelectric focusing; pI markers; aminomethylphenols
Available on request at various institutes of the ASCR
SMV-2017-732: Preparation, testing and delivery of isoelectric point standards
The project continues long-term cooperation of both participants. The low-molecular mass pI markers were synthesized and examined with aim to fill up and deliver the previously described compounds.
SMV-2017-742: Testování možností separace krátkých oligonukleotidů ze vzorku dodaného f. BioVendor, a.s.
Foret, František
2017 - Czech
Available at various institutes of the ASCR
SMV-2017-742: Testování možností separace krátkých oligonukleotidů ze vzorku dodaného f. BioVendor, a.s.
SMV-2016-719: Detection and identification of sources of nanoparticles produced by military equipment
Večeřa, Zbyněk
2016 - Czech
In the study, which took place in a military training area "Vyškov" and simulators University of Defence, we monitored and identified the sources nanoparticles produced various kinds of military equipment. Preliminary results indicate that the source of nanoparticles are especially exhaust gases of engines powering military equipment and studied after shoot fumes. Potential impact of nanoparticles on the service staff of military equipment is currently being evaluated. V rámci studie, která probíhala ve vojenském výcvikovém prostoru „Vyškov“ a na trenažerech Univerzity obrany v Brně, se sledovaly zdroje nanočástic produkovaných různými druhy vojenské techniky. Předběžné výsledky ukazují, že zdrojem nanočástic jsou zejména výfukové zplodiny motorů pohánějících studovanou vojenskou techniku a povýstřelové zplodiny. Možný vliv nanočástic na obsluhu vojenské techniky se v současnosti vyhodnocuje.
Keywords:
nanoparticles
Available on request at various institutes of the ASCR
SMV-2016-719: Detection and identification of sources of nanoparticles produced by military equipment
In the study, which took place in a military training area "Vyškov" and simulators University of Defence, we monitored and identified the sources nanoparticles produced various kinds of military ...
SMV-2016-736: Reaction of plants to presence of CdO nanoparticles in air
Večeřa, Zbyněk
2016 - Czech
Study of the impact of elevated concentrations of nanoparticles of cadmium oxide in the air on Cd content in coniferous Norway spruce (Picea abies) and deciduous beech (Fagus sylvatica). Estimation of the sensitivity of urban forests and woody species to the effects of abiotic stresses and extreme climatic events. Studie vlivu zvýšené koncentrace nanočástic oxidu kademnatého v ovzduší na obsah Cd v jehličnatém smrku ztepilém (Picea abies) a listnatém buku lesním (Fagus sylvatica). Odhad citlivosti městských lesů a dřevin k působení abiotických stresů a extrémních klimatických událostí.
Keywords:
CdO nanoparticles; plants; Picea abies; Fagus sylvatica
Available on request at various institutes of the ASCR
SMV-2016-736: Reaction of plants to presence of CdO nanoparticles in air
Study of the impact of elevated concentrations of nanoparticles of cadmium oxide in the air on Cd content in coniferous Norway spruce (Picea abies) and deciduous beech (Fagus sylvatica). Estimation of ...
SMV-2015-729: Preparation, testing and delivery of isoelectric point standards
Šlais, Karel
2015 - English
The low molecular mass pI markers were prepared, examined and delivered with aim to fill up the previously described pI values. The pI markers comprise compounds based on our original previously described aminomethylphenols. The prepared compounds are the good ampholytes with high hydrophility and molar absorbtivity.
Keywords:
Isoelectric focusing; low molecular mass pI markers; aminomethylphenols
Available on request at various institutes of the ASCR
SMV-2015-729: Preparation, testing and delivery of isoelectric point standards
The low molecular mass pI markers were prepared, examined and delivered with aim to fill up the previously described pI values. The pI markers comprise compounds based on our original previously ...
SMV-2015-706: Tests of apparatus for determination of 3H and 14C in air
Večeřa, Zbyněk
2015 - Czech
Testing of ”V3H14C” apparatus designed for 3H and 14C sampling from the air. The samples are captured into sorbents, silica gel for 3H (THO, T2O), and sodium hydroxide for 14C (14CO2) that are subsequently in laboratory analyzed for quantification of radioactive emissions of 3H and 14C from nuclear power plants e.g. Testování a vývoj zařízení řady ”V3H14C”, která jsou určena k odběru vzorků 3H a 14C ze vzduchu. Vzorky se zachycují do sorbentů, sorbentem pro 3H (THO, T2O) je silikagel, sorbentem pro 14C (14CO2) je vodný roztok 3M hydroxidu sodného. Získané vzorky jsou určeny k následné laboratorní analýze. Analýzou zjištěné hodnoty aktivit odebraných vzorků slouží ke stanovení bilance vypouštěného 3H a 14C např. z jaderných zařízení.
Keywords:
testing; air; radioactive emissions
Available on request at various institutes of the ASCR
SMV-2015-706: Tests of apparatus for determination of 3H and 14C in air
Testing of ”V3H14C” apparatus designed for 3H and 14C sampling from the air. The samples are captured into sorbents, silica gel for 3H (THO, T2O), and sodium hydroxide for 14C (14CO2) that are ...
SMV-2014-719: Measurement of nanoparticles in air
Mikuška, Pavel
2014 - Czech
The study focused on the impact of inhaled nanoparticles on the health status of basic and secondary school pupils based on the measurements of concentration and size distribution of nanoparticles in the air using an aerosol spectrometer SMPS. The nanoparticles were measured in two schools in two small towns and in three schools in Brno. Traffic intensity in near vicinity of schools and children's health asthma problems were investigated too. Studie sledovala dopad inhalovaných nanočástic na zdravotní stav žáků základních a středních škol. Koncentrace a velikostní distribuce nanočástic ve vzduchu byla měřena pomocí aerosolového spektrometru SMPS. Měření nanočástic probíhalo ve 2 školách ve 2 menších městech a ve 3 školách v Brně. Byly sledovány také intensita dopravy v blízkém okolí škol a zdravotní problémy dětí (astma).
Keywords:
nanoparticles, health effect, vehicle emission
Available on request at various institutes of the ASCR
SMV-2014-719: Measurement of nanoparticles in air
The study focused on the impact of inhaled nanoparticles on the health status of basic and secondary school pupils based on the measurements of concentration and size distribution of nanoparticles in ...
SMV-2014-732: Preparation, testing and delivery of isoelectric point standards
Šlais, Karel
2014 - English
The low molecular mass pI markers were prepared, examined and delivered with aim to fill up the previously described pI values. The pI markers comprise compounds based on our original previously described aminomethylphenols. The prepared compounds are the good ampholytes with high hydrophility and molar absorbtivity.
Keywords:
Isoelectric focusing; low molecular mass pI markers; aminomethylphenols
Available on request at various institutes of the ASCR
SMV-2014-732: Preparation, testing and delivery of isoelectric point standards
The low molecular mass pI markers were prepared, examined and delivered with aim to fill up the previously described pI values. The pI markers comprise compounds based on our original previously ...
NRGL provides central access to information on grey literature produced in the Czech Republic in the fields of science, research and education. You can find more information about grey literature and NRGL at service web
Send your suggestions and comments to nusl@techlib.cz
Provider
Other bases