The characterization of the collimated beams of fast neutrons with the CLID detecion system
Ansorge, Martin; Novák, Jan; Majerle, Mitja; Kozic, Ján
2022 - anglický
A new detection device for the measurements of light ions (p, d, t, α) emitted as the products of the nuclear reactions induced by fast neutrons (5-33 MeV) was recently developed at the Nuclear Physics Institute of the Czech Academy of Sciences. The main objective of the Chamber-for-Light-Ion-Detection (CLID) is to produce new differential nuclear data of high interest for the material applications related to fusion and aerospace technologies and to potentially test and validate models of nuclear reactions. Hereby the experimental set-up for the measurements with the CLID is described in detail. The experimental characterization of the collimated fast neutron beams produced by the cyclotron-driven converter (p(35 MeV)+Be(2.5 mm)) is presented. In particular, the implementation of the Proton-Recoil-Telescope technique used for neutron energy spectra determination with the CLID is described.
Klíčová slova:
CLID; collimated fast neutron beams; cyclotron U-120M; NPI; Proton-Recoil-Telescope
Plné texty jsou dostupné v digitálním repozitáři Akademie Věd.
The characterization of the collimated beams of fast neutrons with the CLID detecion system
A new detection device for the measurements of light ions (p, d, t, α) emitted as the products of the nuclear reactions induced by fast neutrons (5-33 MeV) was recently developed at the Nuclear ...
Damping of human vocal folds vibration
Radolf, Vojtěch; Horáček, Jaromír; Bula, Vítězslav; Geneid, A.; Laukkanen, A. M.
2022 - anglický
This study investigates the biomechanics of the end-part of phonation, i.e. the so-called phonation offset, experimentally. This information of vocal fold damping is important for testing and further development of mathematical modelling of phonation. The measurements of the damping ratio, based on high-speed videolaryngoscopic registrations, were realized on a male subject phonating on the vowel [o:]. The results show during the phonation offset a remarkable decrease of vibration frequency of the vocal folds and an increased damping ratio limiting to the value D≈ 0.2. The results for vocal folds’ damping are in agreement with previous measurements performed on humans using different methods.
Klíčová slova:
damping ratio measurement; phonation offset; high-speed videolaryngoscopy
Dokument je dostupný na externích webových stránkách.
Damping of human vocal folds vibration
This study investigates the biomechanics of the end-part of phonation, i.e. the so-called phonation offset, experimentally. This information of vocal fold damping is important for testing and further ...
Design of the magnetically sensitive hydrodynamic bearing for the experimental rotor rig
Ferfecki, P.; Zapoměl, Jaroslav; Molčan, M.
2022 - anglický
In a hydrodynamic bearing, the relative motion between the rotating shaft and stationary housing is separated by a thin film of a lubricant. The magnetically sensitive lubricants with the promise of a semiactive control are able to improve the vibration response of the rotor system supported by the hydrodynamic bearings. A design of the magnetically sensitive hydrodynamic bearing is briefly introduced in this paper. The presented experimental rotor rig is proposed to analyse the large range of load conditions and rotational speeds of the bearing. The designed hydrodynamic bearing is intended to test the ferrofluids, magnetorheological oils, and nano-micro composite magnetic fluids. The apparent viscosity of the magnetically sensitive lubricant is altered by the magnetic field generated by the electric coil and thus the position of the bearing journal is shifted. The experimental measurement results show that the rheological behaviour of the lubrication layer with a magnetorheological fluid is significantly influenced by a magnetic field. The raising magnitude of the current in the electric coil leads to an increase in the bearing's load performance.
Klíčová slova:
magnetically sentivive fluid; hydrodynamic lubrication; sommerfeld number; experimental measurement; load bearing capacity
Dokument je dostupný na externích webových stránkách.
Design of the magnetically sensitive hydrodynamic bearing for the experimental rotor rig
In a hydrodynamic bearing, the relative motion between the rotating shaft and stationary housing is separated by a thin film of a lubricant. The magnetically sensitive lubricants with the promise of a ...
A Bootstrap Comparison of Robust Regression Estimators
Kalina, Jan; Janáček, Patrik
2022 - anglický
The ordinary least squares estimator in linear regression is well known to be highly vulnerable to the presence of outliers in the data and available robust statistical estimators represent more preferable alternatives.
Klíčová slova:
linear regression; robust estimation; nonparametric bootstrap; bootstrap hypothesis testing
Dokument je dostupný na externích webových stránkách.
A Bootstrap Comparison of Robust Regression Estimators
The ordinary least squares estimator in linear regression is well known to be highly vulnerable to the presence of outliers in the data and available robust statistical estimators represent more ...
Determination of aerodynamic coefficients for air flow around U-profiles with different flange porosities
Ledvinková, Blanka; Hračov, Stanislav; Macháček, Michael
2022 - anglický
Our contribution presents the comparison of the experimental investigations and of the numerical 2D simulations of the air flow around U –profiles having different flange porosities. The U-shaped beams were exposed to the air flow having a given velocity at different angles of the wind attack for obtaining the curves of the aerodynamic coefficients depending on the impact angle. The numerical simulations of the wind tunnel testing were performed using the Unsteady Reynolds Averaged Navier-Stokes (RANS) method, k-ω SST turbulence model was assumed.
Klíčová slova:
U-shaped beams; porosity; wind tunnel; RANS simulation; k-ω SST model
Plné texty jsou dostupné v digitálním repozitáři Akademie Věd.
Determination of aerodynamic coefficients for air flow around U-profiles with different flange porosities
Our contribution presents the comparison of the experimental investigations and of the numerical 2D simulations of the air flow around U –profiles having different flange porosities. The U-shaped ...
Theoretical analysis of selected trajectories inscribed by a ball freely rolling in a spherical cavity
Náprstek, Jiří; Fischer, Cyril
2022 - anglický
Indirect monitoring of structures is significantly complicated when an artificial vibration absorber has to be taken into account. Knowledge of the absorber’s behaviour is necessary in order to correctly distinguish the response types obtained during an drive-by measurement. In this work, the mathematical model of the ball-type vibration absorber is used, which is based on the Lagrangian formalism. Three first integrals are identified when no external excitation nor damping is assumed. The paper illustrates the power of this approach, which enables a detailed analysis of free movement of the ball in the spherical cavity. Properties of several particular trajectories depending on initial conditions are presented.
Klíčová slova:
slender structure; vibration absorber; first integral; rolling sphere; structural health monitoring
Plné texty jsou dostupné v digitálním repozitáři Akademie Věd.
Theoretical analysis of selected trajectories inscribed by a ball freely rolling in a spherical cavity
Indirect monitoring of structures is significantly complicated when an artificial vibration absorber has to be taken into account. Knowledge of the absorber’s behaviour is necessary in order to ...
Effect of oscillating blade on tonal noise of blade cascade with five NACA 0010 profiles
Šnábl, Pavel; Pešek, Luděk; Radolf, Vojtěch; Antoš, Pavel; Procházka, Pavel P.; Prasad, Chandra Shekhar
2022 - anglický
The airfoil tonal noise is a well known phenomenon which appears on single airfoils in moderate Reynolds numbers at low angles of attack. It can appear on small aircrafts, fans, wind turbines etc. In thispaper, it was observed on a blade cascade consisting of five NACA 0010 profiles placed in a closed rectangular channel with hard walls when for given conditions, i.e. flow velocity and angle of attack, the cascade tunes to one single frequency. During the middle blade oscillation, the single tone splits up to several tones with lower intensity modulated by the excitation frequency. Thus, the oscillation of one blade suppresses the tonal noise generation in the cascade.
Klíčová slova:
aeroacoustics; blade cascade; trailing edge noise; tonal noise; NACA 0010
Dokument je dostupný na externích webových stránkách.
Effect of oscillating blade on tonal noise of blade cascade with five NACA 0010 profiles
The airfoil tonal noise is a well known phenomenon which appears on single airfoils in moderate Reynolds numbers at low angles of attack. It can appear on small aircrafts, fans, wind turbines etc. In ...
Determination of current floor during mobile robot elevator ride
Krejsa, Jiří; Věchet, Stanislav; Chen, K. S.
2022 - anglický
In order for the mobile robot to use the elevator, it must be capable to call the elevator in, detect the control panel, select desired floor and to determine what floor is the elevator located. The paper deals with determination of correct floor the mobile robot is currently at using the processing of onboard accelerometer data. Up to 5 relative floor difference the method exhibits over 95% accuracy.
Klíčová slova:
mobile robot; elevator floor determination; signal processing
Dokument je dostupný na externích webových stránkách.
Determination of current floor during mobile robot elevator ride
In order for the mobile robot to use the elevator, it must be capable to call the elevator in, detect the control panel, select desired floor and to determine what floor is the elevator located. The ...
Control system architecture for novel experimental microalgae photobioreactor Simbios
Věchet, Stanislav; Krejsa, Jiří; Chen, K. S.
2022 - anglický
Photo-bioreactors for growing biomass based on various microalgae cultures gains interests nowadays due to have possible positive impact to society because of the potential to serve as an atmospheric carbon dioxide removal (CDR) device, produce food or fuel. We present an overall architecture of a control system designed with focus to keep the photo-bioreactor alive for long term continuous operation without any human supervision needed. To test overall control system stability we design a custom build spiral photo-bioreactor (PBR) with novel hyperbolic shaped illuminated part. The shape of the illuminated part was design with the goal to increase the ratio of spiral part to volume due to the fact that the light is crucial for microalgae to grow. The control system was created from scratch while adopting reliable IoT sensors combined with highly reliable custom build embedded control system including a cloud data processing and storage. As a result we have scalable and reliable solution which is suitable for photo-bioreactors of various shapes and sizes to operate in fully autonomous mode without any human supervision needed.
Klíčová slova:
photobioreactor; IoT sensors; control system,
Dokument je dostupný na externích webových stránkách.
Control system architecture for novel experimental microalgae photobioreactor Simbios
Photo-bioreactors for growing biomass based on various microalgae cultures gains interests nowadays due to have possible positive impact to society because of the potential to serve as an atmospheric ...
Correction of gradient pulse shape distortions in radial MRI
Vitouš, Jiří
2022 - anglický
This paper focuses on the optimization of gradient-pulse shapes in MRI measurement. The main topic investigated in this paper is optimization of slice-selective gradient, where imperfections may produce phase distortion in the resulting image and also signal loss in the acquired signal. A method for correction is proposed based on the Nelder-Mead algorithm followed by coordinate ascent search in the neighborhood of the found solution. The adjustment is evaluated using a simple Fast low angle shot (FLASH) sequence with radial readout. The results show a significant improvement in the Free induction decay (FID) signal magnitude, echo stability, and an improvement in the homogeneity of image phase.
Klíčová slova:
MRI; gradient; Nelder–Mead; slice; adjustment
Dokument je dostupný na externích webových stránkách.
Correction of gradient pulse shape distortions in radial MRI
This paper focuses on the optimization of gradient-pulse shapes in MRI measurement. The main topic investigated in this paper is optimization of slice-selective gradient, where imperfections may ...
NUŠL poskytuje centrální přístup k informacím o šedé literatuře vznikající v ČR v oblastech vědy, výzkumu a vzdělávání. Více informací o šedé literatuře a NUŠL najdete na webu služby.
Vaše náměty a připomínky posílejte na email nusl@techlib.cz
Provozovatel
Zahraniční báze